Image Quality and ADC Assessment in Turbo Spin-Echo and Echo-Planar Diffusion-Weighted MR Imaging of Tumors of the Head and Neck.
Panyarak, Wannakamon; Chikui, Toru; Yamashita, Yasuo; Kamitani, Takeshi; Yoshiura, Kazunori.
Afiliación
  • Panyarak W; Graduate School of Dental Science, Kyushu University, Fukuoka, Japan; Division of Oral and Maxillofacial Radiology, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Electronic address: wpanyarak@gmail.com.
  • Chikui T; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan.
  • Yamashita Y; Department of Medical Technology, Kyushu University Hospital, Fukuoka, Japan.
  • Kamitani T; Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan.
  • Yoshiura K; Department of Oral and Maxillofacial Radiology, Faculty of Dental Science, Kyushu University, Fukuoka, Japan.
Acad Radiol ; 26(10): e305-e316, 2019 10.
Article en En | MEDLINE | ID: mdl-30528753
ABSTRACT
RATIONALE AND

OBJECTIVES:

We aimed to compare the distortion ratio (DR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between turbo spin-echo (TSE)-diffusion-weighted imaging (DWI) and echo-planar imaging (EPI)-DWI of the orofacial region and prove the usefulness of TSE-DWI for the differential diagnosis of orofacial lesions. MATERIALS AND

METHODS:

The DR, SNR, and CNR of both sequences were compared in 42 cases. Then, the apparent diffusion coefficient (ADC) of various orofacial lesions obtained by TSE-DWI was investigated in 143 lesions.

RESULTS:

In the first study, 38 of 42 cases were analyzed. TSE-DWI showed a significantly lower DR (p < 0.05) and higher SNR and CNR than EPI-DWI (p < 0.05), indicating the superiority of TSE-DWI. In the second study, 114 cases (79.3%) were successfully analyzed. When lesions were divided into cysts, benign tumors, squamous cell carcinoma, malignant lymphoma, and other malignant tumors (OT), significant differences were observed in all pairs of lesions (p < 0.05) except squamous cell carcinoma and OT (p = 0.877). The area under the curve for distinguishing benign from malignant tumors was 0.80 with a cutoff ADC of 1.29 × 10-3 mm²/s.

CONCLUSION:

TSE-DWI produced better quality images than EPI-DWI. TSE-DWI yields the high possibility of obtaining ADC in the orofacial region, and this value was considered useful for the differential diagnosis of orofacial lesions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Imagen Eco-Planar / Imagen de Difusión por Resonancia Magnética / Neoplasias de Cabeza y Cuello Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Asunto de la revista: RADIOLOGIA Año: 2019 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Asunto principal: Imagen Eco-Planar / Imagen de Difusión por Resonancia Magnética / Neoplasias de Cabeza y Cuello Tipo de estudio: Prognostic_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Acad Radiol Asunto de la revista: RADIOLOGIA Año: 2019 Tipo del documento: Article