Your browser doesn't support javascript.
loading
A Selective Ratiometric Fluorescent Probe for No-Wash Detection of PVC Microplastic.
Caponetti, Valeria; Mavridi-Printezi, Alexandra; Cingolani, Matteo; Rampazzo, Enrico; Genovese, Damiano; Prodi, Luca; Fabbri, Daniele; Montalti, Marco.
Afiliación
  • Caponetti V; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Mavridi-Printezi A; Tecnopolo di Rimini, Via Dario Campana, 71, 47922 Rimini, Italy.
  • Cingolani M; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Rampazzo E; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Genovese D; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Prodi L; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Fabbri D; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
  • Montalti M; Department of Chemistry "Giacomo Ciamician", University of Bologna, Via Selmi 2, 40126 Bologna, Italy.
Polymers (Basel) ; 13(10)2021 May 14.
Article en En | MEDLINE | ID: mdl-34069160
ABSTRACT
Microplastics (MP) are micrometric plastic particles present in drinking water, food and the environment that constitute an emerging pollutant and pose a menace to human health. Novel methods for the fast detection of these new contaminants are needed. Fluorescence-based detection exploits the use of specific probes to label the MP particles. This method can be environmentally friendly, low-cost, easily scalable but also very sensitive and specific. Here, we present the synthesis and application of a new probe based on perylene-diimide (PDI), which can be prepared in a few minutes by a one-pot reaction using a conventional microwave oven and can be used for the direct detection of MP in water without any further treatment of the sample. The green fluorescence is strongly quenched in water at neutral pH because of the formation dimers. The ability of the probe to label MP was tested for polyvinyl chloride (PVC), polyethylene (PE), polyethylene terephthalate (PET), polypropylene (PP), polystyrene (PS), poly methyl methacrylate (PMMA) and polytetrafluoroethylene (PTFE). The probe showed considerable selectivity to PVC MP, which presented an intense red emission after staining. Interestingly, the fluorescence of the MP after labeling could be detected, under excitation with a blue diode, with a conventional CMOS color camera. Good selectivity was achieved analyzing the red to green fluorescence intensity ratio. UV-Vis absorption, steady-state and time-resolved fluorescence spectroscopy, fluorescence anisotropy, fluorescence wide-field and confocal laser scanning microscopy allowed elucidating the mechanism of the staining in detail.
Palabras clave

Texto completo: 1 Colección: 01-internacional Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Italia

Texto completo: 1 Colección: 01-internacional Tipo de estudio: Diagnostic_studies Idioma: En Revista: Polymers (Basel) Año: 2021 Tipo del documento: Article País de afiliación: Italia