Your browser doesn't support javascript.
loading
Technical note: Providing proton fields down to the few-MeV level at clinical pencil beam scanning facilities for radiobiological experiments.
Behrends, Carina; Bäumer, Christian; Verbeek, Nico; Ehlert, Jens; Prasad, Rajendra; Wulff, Jörg; Lühr, Armin; Timmermann, Beate.
Afiliación
  • Behrends C; West German Proton Therapy Centre Essen (WPE), 45147 Essen, Germany.
  • Bäumer C; Department of Physics, TU Dortmund University, 44227 Dortmund, Germany.
  • Verbeek N; West German Cancer Centre (WTZ), University Hospital Essen, 45147 Essen, Germany.
  • Ehlert J; West German Proton Therapy Centre Essen (WPE), 45147 Essen, Germany.
  • Prasad R; Department of Physics, TU Dortmund University, 44227 Dortmund, Germany.
  • Wulff J; West German Cancer Centre (WTZ), University Hospital Essen, 45147 Essen, Germany.
  • Lühr A; German Cancer Consortium (DKTK), 69120 Heidelberg, Germany.
  • Timmermann B; West German Proton Therapy Centre Essen (WPE), 45147 Essen, Germany.
Med Phys ; 49(1): 666-674, 2022 Jan.
Article en En | MEDLINE | ID: mdl-34855985
ABSTRACT

PURPOSE:

The adequate performance of radiobiological experiments using clinical proton beams typically requires substantial preparations to provide the appropriate setup for specific experiments. Providing radiobiologically interesting low-energy protons is a particular challenge, due to various physical effects that become more pronounced with larger absorber thickness and smaller proton energy. This work demonstrates the generation of decelerated low-energy protons from a clinical proton beam.

METHODS:

Monte Carlo simulations of proton energy spectra were performed for energy absorbers with varying thicknesses to reduce the energy of the clinical proton beam down to the few-MeV level corresponding to µ m-ranges. In this way, a setup with an optimum thickness of the absorber with a maximum efficiency of the proton fluence for the provisioning of low-energy protons is supposed to be found. For the specific applications of 2.5-3.3 MeV protons and α -particle range equivalent protons, the relative depth dose was measured and simulated together with the dose-averaged linear energy transfer (LETd) distribution.

RESULTS:

The resulting energy spectra from Monte Carlo simulations indicate an optimal absorber thickness for providing low-energy protons with maximum efficiency of proton fluence at an user-requested energy range for experiments. For instance, providing energies lower than 5 MeV, an energy spectrum with a relative total efficiency of 38.6 % to the initial spectrum was obtained with the optimal setup. The measurements of the depth dose, compared to the Monte Carlo simulations, showed that the dosimetry of low-energy protons works and protons with high LETd down to the range of α -particles can be produced.

CONCLUSIONS:

This work provides a method for generating all clinically and radiobiologically relevant energies - especially down to the few-MeV level - at one clinical facility with pencil beam scanning. Thereby, it enables radiobiological experiments under environmentally uniform conditions.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Protones / Terapia de Protones Tipo de estudio: Health_economic_evaluation Idioma: En Revista: Med Phys Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Asunto principal: Protones / Terapia de Protones Tipo de estudio: Health_economic_evaluation Idioma: En Revista: Med Phys Año: 2022 Tipo del documento: Article País de afiliación: Alemania