A comparative study of human glomerular basement membrane thickness using direct measurement and orthogonal intercept methods.
Viana, Débora Leal; Alladagbin, Dona Jeanne; Dos-Santos, Washington L C; Figueira, Claudio Pereira.
Afiliación
  • Viana DL; Oswaldo Cruz Foundation, Gonçalo Moniz Institute, Rua Waldemar Falcão 121, Candeal, Salvador, BA, CEP 40.295-710, Brazil.
  • Alladagbin DJ; Oswaldo Cruz Foundation, Gonçalo Moniz Institute, Rua Waldemar Falcão 121, Candeal, Salvador, BA, CEP 40.295-710, Brazil.
  • Dos-Santos WLC; Oswaldo Cruz Foundation, Gonçalo Moniz Institute, Rua Waldemar Falcão 121, Candeal, Salvador, BA, CEP 40.295-710, Brazil. washington.santos@fiocruz.br.
  • Figueira CP; Faculty of Medicine, Federal University of Bahia, Salvador, BA, Brazil. washington.santos@fiocruz.br.
BMC Nephrol ; 23(1): 23, 2022 01 10.
Article en En | MEDLINE | ID: mdl-35012461
INTRODUCTION: Here we report estimates of glomerular basement membrane (GBM) thickness in the Brazilian population performed using direct (DM) and orthogonal interception methods (OIM), and comment on potential sources of variation among estimates made by different laboratories. METHODOLOGY: A total of 38 patients, ranging from 3 to 78 years of age, 26 (68%) males and 12 (32%) females, were submitted to kidney biopsy procedures for renal disease diagnosis. Glomeruli were diagnosed with minor histological changes by conventional, immunofluorescence and electron microscopy. GBM thickness was estimated using both DM and OIM methods. RESULTS: Estimates of GBM thickness obtained using DM were higher than those obtained by OIM. However, the application of a correction for non-perpendicular membrane sectioning to DM estimates yielded similar results to those obtained under OIM. The estimated GMB thickness using DM after correction was 289 + 44 nm, versus 287 + 48 nm by OIM. No statistically significant differences were detected in GMB thickness, nor with respect to patient age or sex. CONCLUSIONS: GBM thickness in the studied Brazilian population measured approximately 290 nm. The application of criteria for estimating the shortest distance between the endothelial and podocyte cell membranes with correction for non-perpendicular membrane sectioning can increase the accuracy of GBM thickness estimates using DM and OIM.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Asunto principal: Membrana Basal Glomerular / Enfermedades Renales Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged País/Región como asunto: America do sul / Brasil Idioma: En Revista: Bmc nephrol Asunto de la revista: NEFROLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Brasil

Texto completo: 1 Colección: 01-internacional Asunto principal: Membrana Basal Glomerular / Enfermedades Renales Tipo de estudio: Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Male / Middle aged País/Región como asunto: America do sul / Brasil Idioma: En Revista: Bmc nephrol Asunto de la revista: NEFROLOGIA Año: 2022 Tipo del documento: Article País de afiliación: Brasil