Your browser doesn't support javascript.
loading
Trocar shortening for pediatric vitreoretinal surgery with a 3D printed trocar spacer: Report of two cases.
Di-Luciano, A; Gómez-Nuñez, R; Acosta, F; Rivas-Vega, L; Morales-Cantón, V; Trujillo-Alvarez, M; Cernichiaro-Espinosa, L.
Afiliación
  • Di-Luciano A; Pediatric Retina Unit, Retina and Vitreous Department, Asociación para Evitar la Ceguera en México, IAP, Mexico City, Mexico.
  • Gómez-Nuñez R; Biomedical engineer, private practice, Mexico City, Mexico.
  • Acosta F; CEO, Custom Surgical, Munich, Germany.
  • Rivas-Vega L; Anesthesiology department, Pediatric Retina Unit, Retina and Vitreous Department, Asociación para Evitar la Ceguera en México, IAP, Mexico City, Mexico.
  • Morales-Cantón V; Pediatric Retina Unit, Retina and Vitreous Department, Asociación para Evitar la Ceguera en México, IAP, Mexico City, Mexico.
  • Trujillo-Alvarez M; Pediatric Retina Unit, Retina and Vitreous Department, Asociación para Evitar la Ceguera en México, IAP, Mexico City, Mexico.
  • Cernichiaro-Espinosa L; Pediatric Retina Unit, Retina and Vitreous Department, Asociación para Evitar la Ceguera en México, IAP, Mexico City, Mexico. Electronic address: linda.cernichiaro@retinakids.org.
Arch Soc Esp Oftalmol (Engl Ed) ; 97(8): 473-476, 2022 Aug.
Article en En | MEDLINE | ID: mdl-35914891
ABSTRACT

PURPOSE:

To show the results of a trocar spacer for pediatric vitreoretinal surgery with a 3D printed trocar spacer in 2 cases.

METHODS:

We used standard 27 gauge (ga) and 25 ga trocars and cannulae, and prototyped 1.5 mm × 3 mm spacers with a Prusa MK3 3D printer (0.4 mm nozzle) with Fuse deposition melting (FDM) technology. Parts were printed with a 50 µm layer height in polylactic acid or polylactide (PLA). The spacer was placed in two places between the blade's base and the trocar, and between the trocar and the sclera depending on the desired amount of shortening. This prototype was used in 2 vitrectomy cases in pediatric patients.

RESULTS:

We used this trocar spacer in 2 cases with positive results.

CONCLUSIONS:

This 3D printed spacer has proved to effectively shorten the introduced trocar into two different small eyes. More studies are needed to validate the efficacy and safety of this spacer in clinical practice.