Automated meniscus segmentation and tear detection of knee MRI with a 3D mask-RCNN.
Li, Yuan-Zhe; Wang, Yi; Fang, Kai-Bin; Zheng, Hui-Zhong; Lai, Qing-Quan; Xia, Yong-Fa; Chen, Jia-Yang; Dai, Zhang-Sheng.
Afiliación
  • Li YZ; Department of CT/MRI, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China.
  • Wang Y; Department of CT/MRI, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China.
  • Fang KB; Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China.
  • Zheng HZ; Institute of Biomedical Engineering and Instrumentation, Hangzhou Dianzi University, Hangzhou, China.
  • Lai QQ; Department of CT/MRI, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China.
  • Xia YF; Orthopedics, Anji TCM Hospital Affiliated to Zhejiang Provincial Hospital of Traditional Chinese Medicine (Anji Traditional Chinese Medical Hospital), Anji, 313300, China.
  • Chen JY; Radiology Department, Anxi Hospital of Traditional Chinese Medicine, Quanzhou, 362400, China.
  • Dai ZS; Department of Orthopaedic Surgery, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China. 1009828183@qq.com.
Eur J Med Res ; 27(1): 247, 2022 Nov 14.
Article en En | MEDLINE | ID: mdl-36372871
ABSTRACT

BACKGROUND:

The diagnostic results of magnetic resonance imaging (MRI) are essential references for arthroscopy as an invasive procedure. A deviation between medical imaging diagnosis and arthroscopy results may cause irreversible damage to patients and lead to excessive medical treatment. To improve the accurate diagnosis of meniscus injury, it is urgent to develop auxiliary diagnosis algorithms to improve the accuracy of radiological diagnosis.

PURPOSE:

This study aims to present a fully automatic 3D deep convolutional neural network (DCNN) for meniscus segmentation and detects arthroscopically proven meniscus tears. MATERIALS AND

METHODS:

Our institution retrospectively included 533 patients with 546 knees who underwent knee magnetic resonance imaging (MRI) and knee arthroscopy. Sagittal proton density-weighted (PDW) images in MRI of 382 knees were regarded as a training set to train our 3D-Mask RCNN. The remaining data from 164 knees were used to validate the trained network as a test set. The masks were hand-drawn by an experienced radiologist, and the reference standard is arthroscopic surgical reports. The performance statistics included Dice accuracy, sensitivity, specificity, FROC, receiver operating characteristic (ROC) curve analysis, and bootstrap test statistics. The segmentation performance was compared with a 3D-Unet, and the detection performance was compared with radiological evaluation by two experienced musculoskeletal radiologists without knowledge of the arthroscopic surgical diagnosis.

RESULTS:

Our model produced strong Dice coefficients for sagittal PDW of 0.924, 0.95 sensitivity with 0.823 FPs/knee. 3D-Unet produced a Dice coefficient for sagittal PDW of 0.891, 0.95 sensitivity with 1.355 FPs/knee. The difference in the areas under 3D-Mask-RCNN FROC and 3D-Unet FROC was statistically significant (p = 0.0011) by bootstrap test. Our model detection performance achieved an area under the curve (AUC) value, accuracy, and sensitivity of 0.907, 0.924, 0.941, and 0.785, respectively. Based on the radiological evaluations, the AUC value, accuracy, sensitivity, and specificity were 0.834, 0.835, 0.889, and 0.754, respectively. The difference in the areas between 3D-Mask-RCNN ROC and radiological evaluation ROC was statistically significant (p = 0.0009) by bootstrap test. 3D Mask RCNN significantly outperformed the 3D-Unet and radiological evaluation demonstrated by these results.

CONCLUSIONS:

3D-Mask RCNN has demonstrated efficacy and precision for meniscus segmentation and tear detection in knee MRI, which can assist radiologists in improving the accuracy and efficiency of diagnosis. It can also provide effective diagnostic indicators for orthopedic surgeons before arthroscopic surgery and further promote precise treatment.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Menisco / Lesiones de Menisco Tibial Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Med Res Asunto de la revista: MEDICINA Año: 2022 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Asunto principal: Menisco / Lesiones de Menisco Tibial Tipo de estudio: Diagnostic_studies / Observational_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Eur J Med Res Asunto de la revista: MEDICINA Año: 2022 Tipo del documento: Article País de afiliación: China