Your browser doesn't support javascript.
loading
Breast cancer detection using volatile compound profiles in exhaled breath via selected ion-flow tube mass spectrometry.
Nakayama, Yoshie; Hanada, Mariko; Koda, Hiroshi; Sugimoto, Masahiro; Takada, Masahiro; Toi, Masakazu.
Afiliación
  • Nakayama Y; Breast Medical Oncology, Kyoto University Hospital, Shogoin Kawaramachi 54, Sakyoku, Kyoto 606-8507, Japan.
  • Hanada M; Nissha Co., Ltd, Mibu Hanai-cho, Nakagyo-ku, Kyoto 604-8551, Japan.
  • Koda H; Nissha Co., Ltd, Mibu Hanai-cho, Nakagyo-ku, Kyoto 604-8551, Japan.
  • Sugimoto M; Institute of Medical Science, Tokyo Medical University, 6-1-1 Shinjuku, Shinjuku-ku, Tokyo 160-8402, Japan.
  • Takada M; Breast Medical Oncology, Kyoto University Hospital, Shogoin Kawaramachi 54, Sakyoku, Kyoto 606-8507, Japan.
  • Toi M; Breast Medical Oncology, Kyoto University Hospital, Shogoin Kawaramachi 54, Sakyoku, Kyoto 606-8507, Japan.
J Breath Res ; 17(1)2022 12 08.
Article en En | MEDLINE | ID: mdl-36541460
This study aimed to evaluate volatile compounds in exhaled breath as a non-invasive screening method to detect breast neoplasms. Exhaled breath samples were collected from patients with breast cancer (BC;n= 45) and non-breast cancer (NBC;n= 51) controls. Selected ion-flow tube mass spectrometry was used to quantify the volatile compounds. A multiple logistic regression (MLR) model was developed by combining multiple compounds to discriminate between BC and NBC samples. Amongst the 672 quantified peaks, 17 showed significant differences between BC and NBC samples (P< 0.05 corrected by false discovery rate). Pathway analysis revealed a significant difference in glycerophospholipid metabolism. The MLR model showed an area under the receiver operating characteristic curve (AUC) of 0.719 (95% confidence interval: 0.615-0.822,P< 0.0002). Cross-validation under various conditions resulted in a slight fluctuation in the AUC values, indicating the high generalizability of the MLR model. The model showed a higher BC probability for advanced-stage subjects and higher Ki67 (⩾30) for BC subjects. This study suggests the potential of volatile compounds in exhaled breath as a noninvasive screening method for BC.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Neoplasias de la Mama / Compuestos Orgánicos Volátiles Tipo de estudio: Diagnostic_studies Límite: Female / Humans Idioma: En Revista: J breath res Año: 2022 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Asunto principal: Neoplasias de la Mama / Compuestos Orgánicos Volátiles Tipo de estudio: Diagnostic_studies Límite: Female / Humans Idioma: En Revista: J breath res Año: 2022 Tipo del documento: Article País de afiliación: Japón