Your browser doesn't support javascript.
loading
Vibration Controlled Transient Elastography to Evaluate Steatosis in Candidate Living Donors for Liver Transplantation.
Palte, Eytan; Duong, Jimmy K; Remotti, Helen; Burt, Joseph; Makkar, Jasnit; Samstein, Benjamin; Verna, Elizabeth C; Marratta, Douglas; Emond, Jean C; Fox, Alyson N.
Afiliación
  • Palte E; Department of Medicine, Columbia University Irving Medical Center, New York City, NY.
  • Duong JK; Columbia University Mailman School of Public Health, New York City, NY.
  • Remotti H; Department of Pathology and Cell Biology, Columbia University Irving Medical Center, New York City, NY.
  • Burt J; Department of Pathology and Cell Biology, Columbia University Irving Medical Center, New York City, NY.
  • Makkar J; Department of Radiology, Columbia University Irving Medical Center, New York City, NY.
  • Samstein B; Department of Surgery, Weill Cornell Medicine, New York City, NY.
  • Verna EC; Division of Digestive and Liver Diseases, Department of Medicine, Columbia University Irving Medical Center, New York City, NY.
  • Marratta D; Department of Medicine, Columbia University Irving Medical Center, New York City, NY.
  • Emond JC; Department of Surgery, Columbia University Irving Medical Center, New York City, NY.
  • Fox AN; Division of Digestive and Liver Diseases, Department of Medicine, Columbia University Irving Medical Center, New York City, NY.
Transplantation ; 107(9): 1991-1998, 2023 09 01.
Article en En | MEDLINE | ID: mdl-36959124
ABSTRACT

BACKGROUND:

The ability of vibration controlled transient elastography (VCTE) to reliably exclude significant steatosis in living donor candidates could obviate the need for invasive liver biopsies, expedite the donor approval process, and reduce recipient wait time. We therefore aimed to determine whether VCTE controlled attenuation parameter (CAP) could be used to detect steatosis in potential living donors.

METHODS:

Living donor candidates who presented for evaluation between 2016 and 2019 underwent standard donor workup, VCTE, and liver biopsy if indicated. CAP scores were compared with MRI-Fat Fraction and, when available, histologic fat fraction from liver biopsy. Receiver operating characteristic curves were used to identify cutoffs with appropriate sensitivity and specificity for screening. Statistical analysis was conducted using R (version 3.6.0).

RESULTS:

Seventy-nine candidate living donors presented during the study period, of whom 71 were included in the final analysis and of whom 20 underwent liver biopsy. There was a positive correlation between MRI-Fat Fraction and CAP scores with an observed Spearman correlation coefficient of 0.424 ( P < 0.01). A CAP score of 271.5 dB/m or less was determined to have 89.8% sensitivity and 75% specificity for detecting <5% steatosis on MRI. The correlation between CAP and steatosis of available histologic samples had a Pearson correlation coefficient of 0.603 ( P = 0.005). A CAP cutoff of 276.0 dB/m demonstrated 66.7% sensitivity and 85.7% specificity for detecting <15% histopathologic steatosis and positive and negative predictive values of 71.5% and 82.7%, respectively.

CONCLUSIONS:

VCTE can be integrated into living donor evaluation to accurately screen for hepatic steatosis.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Asunto principal: Trasplante de Hígado / Diagnóstico por Imagen de Elasticidad / Hígado Graso / Enfermedad del Hígado Graso no Alcohólico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Transplantation Año: 2023 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Asunto principal: Trasplante de Hígado / Diagnóstico por Imagen de Elasticidad / Hígado Graso / Enfermedad del Hígado Graso no Alcohólico Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Transplantation Año: 2023 Tipo del documento: Article