Your browser doesn't support javascript.
loading
Optimal assessment for anterior talofibular ligament injury utilizing stress ultrasound entails internal rotation during plantarflexion.
Hattori, Soichi; Onishi, Kentaro; Chan, Calvin K; Yamakawa, Satoshi; Yano, Yuji; Omodani, Toru; Musahl, Volker; Hogan, MaCalus V; Debski, Richard E.
Afiliación
  • Hattori S; MechanoBiology Laboratory, Department of Orthopedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Sports Medicine, Kameda Medical Center, Kamogawa, 15213, Japan. E
  • Onishi K; MechanoBiology Laboratory, Department of Orthopedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Physical Medicine and Rehabilitation, University of Pittsburgh Sc
  • Chan CK; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
  • Yamakawa S; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA.
  • Yano Y; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA.
  • Omodani T; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA.
  • Musahl V; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA; Department of Orthopedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA.
  • Hogan MV; MechanoBiology Laboratory, Department of Orthopedic Surgery, University of Pittsburgh School of Medicine, Pittsburgh, PA 15213, USA; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, U
  • Debski RE; Orthopedic Robotics Laboratory, University of Pittsburgh, Pittsburgh, PA 296-8602, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA 15213, USA.
J ISAKOS ; 9(3): 302-308, 2024 Jun.
Article en En | MEDLINE | ID: mdl-38342182
ABSTRACT

OBJECTIVES:

An optimal load and ankle position for stress ultrasound of the injured anterior talofibular ligament (ATFL) are unknown. The objectives of this study were to compare stress ultrasound and ankle kinematics from a 6 degree-of-freedom (6-DOF) robotic testing system as a reference standard for the evaluation of injured ATFL and suggest cut-off values for ultrasound diagnosis.

METHODS:

Ten fresh-frozen human cadaveric ankles were used. Loads and ankle positions examined by the 6-DOF robotic testing system were 40 N anterior load, 1.7 Nm inversion, and 1.7 Nm internal rotation torques at 30° plantarflexion, 15° plantarflexion, and 0° plantarflexion. Bony translations were measured by ultrasound and a robotic testing system under the above conditions. After measuring the intact ankle, ATFL was transected at its fibular attachment under arthroscopy. Correlations between ultrasound and robotic testing systems were calculated with Pearson correlation coefficients. Paired t-tests were performed for comparison of ultrasound measurements of translation between intact and transected ATFL and unloaded and loaded conditions in transected ATFL.

RESULTS:

Good agreement between ultrasound measurement and that of the robotic testing system was found only in internal rotation at 30° plantarflexion (ICC â€‹= â€‹0.77; 95% confidence interval 0.27-0.94). At 30° plantarflexion, significant differences in ultrasound measurements of translation between intact and transected ATFL (p â€‹< â€‹0.01) were found in response to 1.7 Nm internal rotation torque and nonstress and stress with internal rotation (p â€‹< â€‹0.01) with mean differences of 2.4 â€‹mm and 1.9 â€‹mm, respectively.

CONCLUSION:

Based on the data of this study, moderate internal rotation and plantarflexion are optimal to evaluate the effects of ATFL injury when clinicians utilize stress ultrasound in patients. LEVEL OF EVIDENCE III.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Cadáver / Ultrasonografía / Traumatismos del Tobillo / Ligamentos Laterales del Tobillo / Articulación del Tobillo Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J ISAKOS Año: 2024 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Asunto principal: Cadáver / Ultrasonografía / Traumatismos del Tobillo / Ligamentos Laterales del Tobillo / Articulación del Tobillo Límite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J ISAKOS Año: 2024 Tipo del documento: Article