Your browser doesn't support javascript.
loading
A Radical-Generating Probe to Release Free Fluorophores and Identify Artemisinin-Sensitive Cancer Cells.
Chen, Chen; Chen, Yi-Xin; Zhang, Chong-Jing.
Afiliación
  • Chen C; State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Beijing Key Laboratory of Active Substance Discovery and Druggability Evaluation, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China.
  • Chen YX; State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Beijing Key Laboratory of Active Substance Discovery and Druggability Evaluation, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China.
  • Zhang CJ; State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Beijing Key Laboratory of Active Substance Discovery and Druggability Evaluation, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China.
ACS Sens ; 9(5): 2310-2316, 2024 05 24.
Article en En | MEDLINE | ID: mdl-38651676
ABSTRACT
The smart light-up probes have been extensively developed to image various enzymes and other bioactive molecules. Upon activation, these probes result in light-up fluorophores that exist in a protein-bound or a free form. The difference between these two forms has not yet been reported. Here, we present a pair of smart light-up probes that generate a protein-bound fluorophore and a free fluorophore upon activation by heme. Probe 8 generated a radical-attached fluorophore that predominantly existed in the free form, while probe 10 generated an α,ß-unsaturated ketone-attached fluorophore that showed extensive labeling of proteins. In live-cell imaging, probe 8 showed greater fluorescence intensity than probe 10 when low concentrations (0.1-5 µM) of the probes were used, but probe 8 was less fluorescent than probe 10 when the concentrations of the probes were high (10 µM). Finally, probe 8 was used to reflect the activation level of the endoperoxide bond in cancer cells and to effectively distinguish ART-sensitive cancer cells from ART-insensitive ones.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Artemisininas / Colorantes Fluorescentes Límite: Humans Idioma: En Revista: ACS Sens Año: 2024 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Asunto principal: Artemisininas / Colorantes Fluorescentes Límite: Humans Idioma: En Revista: ACS Sens Año: 2024 Tipo del documento: Article País de afiliación: China