Your browser doesn't support javascript.
loading
Electrochemical Nanosensor for the Simultaneous Determination of Anticancer Drugs Epirubicin and Topotecan Using UiO-66-NH2/GO Nanocomposite Modified Electrode.
Tajik, Somayeh; Shams, Parisa; Beitollahi, Hadi; Garkani Nejad, Fariba.
Afiliación
  • Tajik S; Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 76169-13555, Iran.
  • Shams P; Department of Anatomical Sciences, Afzalipour School of Medicine, Kerman University of Medical Sciences, Kerman 76169-13555, Iran.
  • Beitollahi H; Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76318-85356, Iran.
  • Garkani Nejad F; Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman 76318-85356, Iran.
Biosensors (Basel) ; 14(5)2024 May 04.
Article en En | MEDLINE | ID: mdl-38785703
ABSTRACT
In this work, UiO-66-NH2/GO nanocomposite was prepared using a simple solvothermal technique, and its structure and morphology were characterized using field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). An enhanced electrochemical sensor for the detection of epirubicin (EP) was proposed, which utilized a UiO-66-NH2/GO nanocomposite-modified screen-printed graphite electrode (UiO-66-NH2/GO/SPGE). The prepared UiO-66-NH2/GO nanocomposite improved the electrochemical performance of the SPGE towards the redox reaction of EP. Under optimized experimental conditions, this sensor demonstrates a remarkable limit of detection (LOD) of 0.003 µM and a linear dynamic range from 0.008 to 200.0 µM, providing a highly capable platform for sensing EP. Furthermore, the simultaneous electro-catalytic oxidation of EP and topotecan (TP) was investigated at the UiO-66-NH2/GO/SPGE surface utilizing differential pulse voltammetry (DPV). DPV measurements revealed the presence of two distinct oxidation peaks of EP and TP, with a peak potential separation of 200 mV. Finally, the UiO-66-NH2/GO/SPGE sensor was successfully utilized for the quantitative analysis of EP and TP in pharmaceutical injection, yielding highly satisfactory results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Epirrubicina / Topotecan / Electrodos / Nanocompuestos / Técnicas Electroquímicas / Grafito / Antineoplásicos Límite: Humans Idioma: En Revista: Biosensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Asunto principal: Epirrubicina / Topotecan / Electrodos / Nanocompuestos / Técnicas Electroquímicas / Grafito / Antineoplásicos Límite: Humans Idioma: En Revista: Biosensors (Basel) Año: 2024 Tipo del documento: Article País de afiliación: Irán