Your browser doesn't support javascript.
loading
Magnetic Rubber@Ni-Co layered double hydroxide derived from ZIF-67 template as nanostructured sorbent; application in determination of anticancer drugs in plasma samples.
Riazi Bonab, Hanieh; Abbas Matin, Amir; Heidari, Hassan; Soylak, Mustafa.
Afiliación
  • Riazi Bonab H; Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
  • Abbas Matin A; Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran. Electronic address: matinchem@gmail.com.
  • Heidari H; Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
  • Soylak M; Erciyes University, Faculty of Sciences, Department of Chemistry, 38039 Kayseri, Türkiye; Technology Research and Application Center (ERU-TAUM), Erciyes University, 38039 Kayseri, Türkiye; Turkish Academy of Sciences (TUBA), Çankaya, Ankara, Türkiye.
Article en En | MEDLINE | ID: mdl-38851151
ABSTRACT
In this study, a magnetic three-dimensional nano-composite based on Rubber-Fe3O4@Ni-Co Layered double hydroxide derived from ZIF-67 template was synthesized by a hydrothermal method. The proposed nano-composite was used as a sorbent for the enrichment of trace amounts of anti-cancer drugs (dasatinib and erlotinib hydrochloride) from plasma samples followed by determination using high-performance liquid chromatographic analysis (HPLC-UV). The synthesized nano-sorbent was characterized by X-ray diffraction, field emission scanning electron microscopy, Fourier transform infrared spectroscopy, vibrating-sample magnetometer, Brunauer-Emmett-Teller surface analysis, Barrett-Joyner-Halenda pore size analysis and energy dispersive X-ray spectroscopy. Under optimal experimental conditions, factors affecting on extraction efficiency such as pH, ionic strength, extraction temperature and time, desorption solvent and time, the limit of detection (LODs) and the limit of quantification (LOQs) were obtained as 0.6, 2 µg/L for both of dasatinib and erlotinib, respectively. Also, linear range of the method were 2-500 and 2-1000 µg/L for dasatinib and erlotinib, respectively. Relative standard deviations (RSD%) for the repeatability of extraction on sorbent to sorbent were obtained as 3.59, 1.97 %, and one sorbent reusability were investigated and relative standard deviation values were obtained 5.35, 3.30 % for dasatinib and erlotinib, respectively.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Asunto principal: Goma / Límite de Detección / Clorhidrato de Erlotinib / Antineoplásicos Límite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Asunto principal: Goma / Límite de Detección / Clorhidrato de Erlotinib / Antineoplásicos Límite: Humans Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2024 Tipo del documento: Article País de afiliación: Irán