Your browser doesn't support javascript.
loading
Feasibility study of treatment of mixed astigmatism with small-incision lenticule extraction (SMILE) by using research software.
Ganesh, Sri; Brar, Sheetal; Bose, Shilpi; Shah, Mamta Lakhana.
Afiliación
  • Ganesh S; Phaco and Refractive Services, Nethradhama Super Specialty Eye Hospital, Bengaluru, Karnataka, India.
Indian J Ophthalmol ; 72(7): 1056-1063, 2024 Jul 01.
Article en En | MEDLINE | ID: mdl-38905464
ABSTRACT

PURPOSE:

To report the preliminary experience and initial clinical results following SMILE for the treatment of mixed astigmatism.

METHODS:

Thirteen eyes of nine patients with a mean age of 27 ± 4.36 years were included in the series. In 8/13 eyes, myopic SMILE license and in 4/13 eyes, hyperopic SMILE license (available as part of an open/research software) was used for the treatment. The mean follow-up was 9.5 ± 8.7 (0.5-24) months, and the median follow-up was 6 months.

SETTING:

Nethradhama Superspeciality Eye Hospital, Bangalore, India.

DESIGN:

Exploratory study.

RESULTS:

The mean preoperative sphere, cylinder, and spherical equivalent (SE) were 1.44 ± 1.63, -2.70 ± 2.30, and -0.24 ± 1.14 D, which changed to -0.03 ± 0.30, -0.28 ± 0.48, and -0.18 ± 0.49 D, respectively, 6 months postoperatively. Furthermore, 85% (11/13) eyes were within ± 0.50 D, 92% (12/13) eyes were within ± 1.00 D, while all eyes were within ± 1.50 D of SE correction. All eyes were within ± 1.00 D of cylinder correction. In addition, 92% (12/13) eyes had UDVA better than 20/32, with 54% (7/13) eyes having UDVA 20/20 or better. Safety and efficacy indices were 1.08 and 0.92, respectively. No eyes lost more than 1 line of CDVA. The mean corneal higher order aberrations (HOA) increased from 0.111 ± 0.048 to 0.209 ± 0.056 (P < 0.001). The mean objective scatter index (OSI) did not show a significant change (pre = 0.71 ± 0.69, 6 months = 0.89 ± 0.20; P = 0.35).

CONCLUSION:

Early experience showed that SMILE was feasible for the management of eyes with mixed astigmatism, without any intraoperative complications, unique to the procedure.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Asunto principal: Refracción Ocular / Astigmatismo / Agudeza Visual / Estudios de Factibilidad / Sustancia Propia / Topografía de la Córnea / Cirugía Laser de Córnea Límite: Adult / Female / Humans / Male Idioma: En Revista: Indian J Ophthalmol Año: 2024 Tipo del documento: Article País de afiliación: India

Texto completo: 1 Colección: 01-internacional Asunto principal: Refracción Ocular / Astigmatismo / Agudeza Visual / Estudios de Factibilidad / Sustancia Propia / Topografía de la Córnea / Cirugía Laser de Córnea Límite: Adult / Female / Humans / Male Idioma: En Revista: Indian J Ophthalmol Año: 2024 Tipo del documento: Article País de afiliación: India