Your browser doesn't support javascript.
loading
Correlation between myocardial velocity measured using tissue doppler imaging in the left ventricular lead-implanted segment and response to cardiac resynchronization therapy
Yang, Dong-Mei; Yu, Fei; Chen, Kang-Yu; Su, Hao; Wang, Qi; Liu, Zhi-Quan; Hu, Kai; Xu, Jian; Yan, Ji.
Afiliação
  • Yang, Dong-Mei; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Yu, Fei; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Chen, Kang-Yu; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Su, Hao; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Wang, Qi; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Liu, Zhi-Quan; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Hu, Kai; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Xu, Jian; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
  • Yan, Ji; First Affiliated Hospital of the University of Science and Technology of China. Division of Cardiology. Hefei. CN
Clinics ; 74: e1077, 2019. tab, graf
Article em En | LILACS | ID: biblio-1039556
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVES:

This study investigated whether tissue Doppler imaging parameters, especially the peak systolic velocity of the left ventricular lead-implanted segment (Ss), affect cardiac resynchronization therapy response.

METHODS:

In this case-control study, 110 enrolled patients were divided into cases (responder group, n=65) and controls (nonresponder group, n=45) based on whether their left ventricular end-systolic volume was reduced by ≥15% at 6 months after surgery. Preoperative clinical and echocardiographic data were collected. Multivariate logistic regression models were used to analyze the factors affecting the response to cardiac resynchronization therapy, and receiver operating characteristic curves were plotted to evaluate their diagnostic values.

RESULTS:

The proportion of patients with left bundle branch block in the case group was higher than that in the control group. The control group showed a higher left atrial volume index, E/A ratio and E/Em ratio but lower Ss than that of the case group. A multivariate regression analysis showed that left bundle branch block, Ss, and an E/Em ratio>14 were independent risk factors affecting the response to cardiac resynchronization therapy. Ss=4.1 cm/s was the best diagnostic threshold according to the receiver operating characteristic curve.

CONCLUSIONS:

Ss is an important factor affecting the response to cardiac resynchronization therapy. Patients with heart failure associated with Ss<4.1 cm/s have a higher risk of nonresponse.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: LILACS Assunto principal: Ecocardiografia Doppler / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Ventrículos do Coração Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Clinics Assunto da revista: MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: LILACS Assunto principal: Ecocardiografia Doppler / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Ventrículos do Coração Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Clinics Assunto da revista: MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: China