Dependência de Pacing a Longo-Prazo e Preditores de Implante de Pacemaker após Implante Percutâneo de Prótese Valvular Aórtica - 1 Ano de Seguimento / Long-Term Ventricular Pacing Dependency and Pacemaker Implantation Predictors after Transcatheter Aortic Valve Replacement - A 1-Year Follow-Up
Arq. bras. cardiol
; 119(4): 522-530, Oct. 2022. tab, graf
Artigo
em Português
|
LILACS-Express
| LILACS
| ID: biblio-1403353
Biblioteca responsável:
BR1.1
RESUMO
Resumo Fundamento Os distúrbios de condução (DC) são a complicação mais frequente após a substituição da válvula aórtica transcateter (TAVR) e ainda não há consenso sobre seu tratamento. Objetivo Avaliar novos DC e implante de marca-passo definitivo (MPD) após a TAVR e avaliar a porcentagem de estimulação ventricular (EV) até 1 ano de acompanhamento. Métodos Pacientes submetidos a TAVR de outubro de 2014 a novembro de 2019 foram cadastrados; pacientes com MPD anterior foram excluídos. Dados clínicos, do procedimento, do ECG e do MPD foram coletados até 1 ano após o implante. O nível de significância adotado para a análise estatística foi 0,05%. Resultados Um total de 340 indivíduos foram submetidos a TAVR. O DC mais comum foi bloqueio de ramo esquerdo novo (BRE; 32,2%), sendo que 56% destes foram resolvidos após 6 meses. O bloqueio do ramo direito (BRD) foi o maior fator de risco para bloqueio atrioventricular avançado (BAV) [RC=8,46; p<0,001] e implante de MPD [RC=5,18; p<0,001], seguido de BAV de baixo grau prévio [RC=2,25; p=0,016 para implante de MPD]. Em relação às características do procedimento, válvulas de gerações mais recentes e procedimentos de válvula-em-válvula foram associados a menos DC. No total, 18,5% dos pacientes tiveram MPD implantado após a TAVR. Na primeira avaliação do MPD, pacientes com BAV avançado tinham uma porcentagem mediana de EV de 80%, e, após um ano, de 83%. Em relação aos pacientes com BRE e BAV de baixo grau, a EV mediana foi mais baixa (6% na primeira avaliação, p=0,036; 2% após um ano, p = 0,065). Conclusão O BRE foi o DC mais frequente após a TAVR, com mais da metade dos casos se resolvendo nos primeiros 6 meses. O BRD foi o principal fator de risco para BAV avançado e implante de MPD. O BAV avançado foi associado a uma porcentagem mais alta de EV no acompanhamento de 1 ano.
ABSTRACT
Abstract Background Conduction disturbances (CD) are the most frequent complication after transcatheter aortic valve replacement (TAVR), and there continues to be a lack of consensus on their management. Objective To assess new CD and permanent pacemaker (PPM) implantation after TAVR and to evaluate the ventricular pacing percentage (VP) up to 1 year of follow-up. Methods Patients who underwent TAVR from October 2014 to November 2019 were enrolled; patients with previous PPM were excluded. Clinical, procedure, ECG, and PPM data were collected up to 1 year after implantation. The significance level adopted in the statistical analysis was 0.05. Results A total of 340 patients underwent TAVR. The most frequent CD was the new left bundle branch block (LBBB; 32.2%), which 56% resolved after 6 months. Right bundle branch block (RBBB) was the biggest risk factor for advanced atrioventricular block (AVB) [OR=8.46; p<0.001] and PPM implantation [OR=5.18, p<0.001], followed by previous low-grade AVB [OR=2.25; p=0.016 for PPM implantation]. Regarding procedure characteristics, newer generation valves and valve-in-valve procedures were associated with fewer CDs. Overall, 18.5% of patients had a PPM implanted post-TAVR. At first PPM evaluation, patients with advanced AVB had a median percentage of VP of 80% and 83% at one year. Regarding patients with LBBB plus low-grade AVB, median VP was lower (6% at first assessment, p=0.036; 2% at one year, p = 0.065). Conclusion LBBB was the most frequent CD after TAVR, with more than half being resolved in the first six months. RBBB was the major risk factor for advanced AVB and PPM implantation. Advanced AVB was associated with a higher percentage of VP at 1 year of follow-up.
Aortic Valve Stenosis; Atrioventriclar Block; Bloqueio Atrioventricular; Cardiac Conduction System Disease; Distúrbios de Condução Cardíaca; Estenose Aórtica; Heart Valve Prosthesis Implantation; Implante Marcapasso; Implante Prótese Valvar Aórtica; Pacemaker,Artificial; Substituição Valva Aórtica Transcateter; Transcatheter Aortic Valve Replacement
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Temas:
Geral
Base de dados:
LILACS
Tipo de estudo:
Prognostic_studies
/
Risk_factors_studies
Idioma:
Português
Revista:
Arq. bras. cardiol
Assunto da revista:
Cardiologia
Ano de publicação:
2022
Tipo de documento:
Artigo
País de afiliação:
Portugal
Instituição/País de afiliação:
Centro Hospitalar Universitário de São João/PT
Similares
MEDLINE
...
LILACS
LIS