Versão Brasileira do Questionário de Satisfação com a Prótese (SAT-PRO/Br): validade estrutural, validade concorrente, consistência interna e estabilidade / Brazilian version of the Prosthesis Satisfaction Questionnaire (SAT-PRO/Br): structural validity, concurrent validity, internal consistency and stability
Acta fisiátrica
; 29(4): 282-288, dez. 2022.
Article
em Pt
|
LILACS-Express
| LILACS
| ID: biblio-1416501
Biblioteca responsável:
BR1531.9
RESUMO
Objetivo:
Analisar as propriedades psicométricas do SAT-PRO/Br através da observação da validade estrutural e concorrente, consistência interna e estabilidade.Método:
A amostra deste estudo transversal foi consecutiva, não probabilística, constituída por 128 idosos com amputação de membro inferior, com amputação unilateral e que utilizavam a prótese a pelo menos um ano. As propriedades psicométricas foram avaliadas através da validade estrutural (Comparative Fit Index- CFI, Tucker-Lewis Index-TLI, Root Means Square Error of Approximation-RMSEA e Standardized Root Mean Residual-SRMR), validade concorrente utilizando a versão brasileira da Trinity Amputation and Prosthesis Experience Scales - Revised (TAPES-R), além da consistência interna dos itens pelo alfa de Cronbach e estabilidade pelo Intraclass Correlacion Coefficient (ICC).Resultados:
O SAT-PRO/Br e a TAPES-R apresentaram forte correlação em relação a validade concorrente. A estabilidade variou de 0,85 a 0,91 através do ICC. Os índices de modelo do ajuste apresentaram valores de CFI de 0,991, TLI de 0,989, RMSEA de 0,045 e o SRMR de 0,074. Observou-se uma boa consistência interna com alfa de Cronbach total de 0.91.Conclusão:
As propriedades psicométricas deste estudo sobre o SAT-PRO/Br levam a concluir que esta versão é válida, confiável e apresenta boa consistência interna e estabilidade para ser aplicada em idosos brasileiros amputados de membro inferior.ABSTRACT
Objective:
To analyze the psychometric properties of the SAT-PRO/Br through the observation of structural and concurrent validity, internal consistency and stability.Method:
The sample of this cross-sectional study was consecutive, non-probabilistic, consisting of 128 elderly with lower limb amputation, with unilateral amputation and who used the prosthesis for at least one year. The psychometric properties were evaluated through structural validity (Comparative Fit Index- CFI, Tucker-Lewis Index-TLI, Root Means Square Error of Approximation-RMSEA and Standardized Root Mean Residual-SRMR), concurrent validity using the Brazilian version of Trinity Amputation and Prosthesis Experience Scales - Revised (TAPES-R), in addition to the internal consistency of the items by Cronbach's alpha and stability by the Intraclass Correlacion Coefficient (ICC).Results:
The SAT-PRO/Br and TAPES-R showed a strong correlation in relation to concurrent validity. Stability ranged from 0.85 to 0.91 across the ICC. The fit model indices showed CFI values of 0.991, TLI of 0.989, RMSEA of 0.045 and SRMR of 0.074. A good internal consistency was observed with a total Cronbach's alpha of 0.91.Conclusion:
The psychometric properties of this study on the SAT-PRO/Br lead to the conclusion that this version is valid, reliable and has good internal consistency and stability to be applied to elderly Brazilians with lower limb amputees.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Tipo de estudo:
Observational_studies
/
Prevalence_studies
País/Região como assunto:
America do sul
/
Brasil
Idioma:
Pt
Revista:
Acta fisiátrica
Assunto da revista:
MEDICINA FISICA E REABILITACAO
Ano de publicação:
2022
Tipo de documento:
Article
País de afiliação:
Brasil
/
Portugal