Método manométrico alternativo de calibración de transductores de presión para la monitorización hemodinámica invasiva / Alternative manometric method of calibration of pressure transducers for invasive hemodynamic monitoring
Rev. cuba. anestesiol. reanim
; 16(2): 12-18, may.-ago. 2017. ilus, tab
Artigo
em Espanhol
| LILACS, CUMED
| ID: biblio-960304
Biblioteca responsável:
CU1.1
RESUMEN
Introducción:
La calibración de los transductores tiene gran importancia para la medición precisa de las presiones, durante la monitorización hemodinámica invasiva de los pacientes que requieren observación estrecha en las unidades de atención al grave y en el quirófano.Objetivo:
Desarrollar y validar un método de calibración para transductores de presión, sencillo, eficaz y de bajo costo.Métodos:
Se desarrolló un método manométrico alternativo, basado en la ley de Pascal, para la calibración de los transductores de presión durante la monitorización hemodinámica invasiva que se realiza en la Unidad de Cuidados Intensivos de Cirugía Cardiovascular del Hospital Clínico-Quirúrgico Hermanos Ameijeiras. Este método fue validado mediante la comparación con el estándar recomendado en un total de 215 pacientes que requirieron monitorización hemodinámica invasiva entre los meses de enero y junio del 2015.Resultados:
Con el método manométrico alternativo creado se obtiene el mismo resultado que con el método hidráulico recomendado por la literatura.Conclusiones:
El método alternativo creado es preciso, eficaz y costo-efectivo(AU)ABSTRACT
Introduction:
Transducer calibration is very important for the accurate measurement of pressures during invasive hemodynamic monitoring of patients requiring close observation in the primary care units and in the operating room.Objective:
To develop and validate a method of calibration of pressure transducers, which is simple, efficient and low-cost.Methods:
An alternative manometric method, based on Pascal's law, was developed for the calibration of pressure transducers during invasive hemodynamic monitoring performed at the intensive care unit of the cardiovascular surgery department at Hermanos Ameijeiras Clinical-Surgical Hospital. This method was validated by its comparison with the recommended standard in a total of 215 patients who required invasive hemodynamic monitoring between January and June 2015.Results:
With the alternative manometric method created, the same result was obtained as with the hydraulic method recommended by the literature.Conclusions:
The alternative method created is accurate, efficient and cost-effective(AU)
Texto completo:
Disponível
Coleções:
Bases de dados internacionais
Temas:
Geral
Base de dados:
LILACS
Assunto principal:
Transdutores de Pressão
/
Calibragem
Tipo de estudo:
Prognostic_studies
Limite:
Humanos
Idioma:
Espanhol
Revista:
Rev. cuba. anestesiol. reanim
Assunto da revista:
Anestesiologia
Ano de publicação:
2017
Tipo de documento:
Artigo
País de afiliação:
Cuba
Instituição/País de afiliação:
Hospital Clínico Quirúrgico Hermanos Ameijeiras/CU
Similares
MEDLINE
...
LILACS
LIS