Improved liquid chromatographic method for mitoxantrone quantification in mouse plasma and tissues to study the pharmacokinetics of a liposome entrapped mitoxantrone formulation.
J Chromatogr B Analyt Technol Biomed Life Sci
; 799(1): 149-55, 2004 Jan 05.
Article
em En
| MEDLINE
| ID: mdl-14659447
A simple, rapid HPLC method for quantification of mitoxantrone in mouse plasma and tissue homogenates in the presence of a liposome entrapped mitoxantrone formulation (LEM-ETU) is described. Sample preparation is achieved by protein precipitation of 100 microl plasma or 200 microl tissue homogenate with an equal volume of methanol containing 0.5 M hydrochloric acid:acetonitrile (90:10, v/v). Ametantrone is used as the internal standard (i.s.). Mitoxantrone and i.s. are separated on a C18 reversed phase HPLC column, and quantified by their absorbance at 655 nm. In plasma, the standard curve is linear from 5 to 1000 ng/ml, and the precision (%CV) and accuracy (percentage of nominal concentration) are within 10%. In mouse tissue (heart, kidney, liver, lung, and spleen) homogenates (5%, w/v), the standard curve is linear from 25 to 2000 ng/ml, with acceptable precision and accuracy. The method was used to successfully quantify mitoxantrone in mouse plasma and tissue samples to support a pharmacokinetic study of LEM-ETU in mice.
Buscar no Google
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Cromatografia Líquida de Alta Pressão
/
Mitoxantrona
/
Antineoplásicos
Tipo de estudo:
Diagnostic_studies
Limite:
Animals
Idioma:
En
Revista:
J Chromatogr B Analyt Technol Biomed Life Sci
Assunto da revista:
ENGENHARIA BIOMEDICA
Ano de publicação:
2004
Tipo de documento:
Article
País de afiliação:
Estados Unidos