Evaluation of 2-column agglutination versus conventional tube technique for antibody screening.
East Mediterr Health J
; 9(3): 407-12, 2003 May.
Article
em En
| MEDLINE
| ID: mdl-15751934
The study aimed to determine the specificity and sensitivity of the Ortho BioVue two-column agglutination system for the detection of low concentrations of clinically significant antibodies in serum. The BioVue system was compared with the conventional tube technique (LISS-Coombs indirect antiglobulin test), and the two-stage Papenzyme test was used to resolve discrepancies between the two methods. We tested 3000 serum samples from randomly selected patients at King Hussein Medical Centre. Both the antibody screening and identification gave negative results in 2952 patients and positive results in 48 patients. We found the BioVue system to be the more sensitive technique. However, if papain enzyme-treated cells were included in the conventional tube technique when applied to antibody screening and identification, both methods would be of comparable sensitivity.
Buscar no Google
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Teste de Coombs
/
Testes de Hemaglutinação
/
Programas de Rastreamento
/
Anticorpos
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Screening_studies
Limite:
Humans
País/Região como assunto:
Asia
Idioma:
En
Revista:
East mediterr health j
Assunto da revista:
MEDICINA
Ano de publicação:
2003
Tipo de documento:
Article
País de afiliação:
Jordânia