Your browser doesn't support javascript.
loading
The RBE issues in ion-beam therapy: conclusions of a joint IAEA/ICRU working group regarding quantities and units.
Wambersie, A; Hendry, J H; Andreo, P; DeLuca, P M; Gahbauer, R; Menzel, H; Whitmore, G.
Afiliação
  • Wambersie A; International Commission on Radiation Units and Measurements, Bethesda, Maryland, USA. Andre.Wambersie@imre.ucl.ac.be
Radiat Prot Dosimetry ; 122(1-4): 463-70, 2006.
Article em En | MEDLINE | ID: mdl-17229786
ABSTRACT
This paper summarises the conclusions of a working group established jointly by the International Atomic Energy Agency (IAEA) and the International Commission on Radiation Units and Measurements (ICRU) to address some of the relative biological effectiveness (RBE) issues encountered in ion-beam therapy. Special emphasis is put on the selection and definition of the involved quantities and units. The isoeffective dose, as introduced here for radiation therapy applications, is the dose that delivered under reference conditions would produce the same clinical effects as the actual treatment in a given system, all other conditions being identical. It is expressed in Gy. The reference treatment conditions are photon irradiation, 2 Gy per fraction, 5 daily fractions a week. The isoeffective dose D(IsoE) is the product of the physical quantity absorbed dose D and a weighting factor W(IsoE). W(IsoE) is an inclusive weighting factor that takes into account all factors that could influence the clinical effects like dose per fraction, overall time, radiation quality (RQ), biological system and effects. The numerical value of W(IsoE) is selected by the radiation-oncology team for a given patient (or treatment protocol). It is part of the treatment prescription. Evaluation of the influence of RQ on W(IsoE) raises complex problems because of the clinically significant RBE variations with biological effect (late vs. early) and position in depth in the tissues which is a problem specific to ion-beam therapy. Comparison of the isoeffective dose with the equivalent dose frequently used in proton- and ion-beam therapy is discussed.
Assuntos
Buscar no Google
Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Radiometria / Eficiência Biológica Relativa / Planejamento da Radioterapia Assistida por Computador / Guias de Prática Clínica como Assunto / Radioterapia Conformacional / Radioterapia com Íons Pesados Tipo de estudo: Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Radiometria / Eficiência Biológica Relativa / Planejamento da Radioterapia Assistida por Computador / Guias de Prática Clínica como Assunto / Radioterapia Conformacional / Radioterapia com Íons Pesados Tipo de estudo: Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2006 Tipo de documento: Article País de afiliação: Estados Unidos