The estimation of the thyroid volume before surgery--an important prerequisite for minimally invasive thyroidectomy.
Langenbecks Arch Surg
; 393(5): 721-4, 2008 Sep.
Article
em En
| MEDLINE
| ID: mdl-18690473
ABSTRACT
INTRODUCTION:
Actually, thyroid volume >25 ml, obtained by preoperative ultrasound evaluation, is a very important exclusion criteria for minimally invasive thyroidectomy. So far, among different imaging techniques, two-dimensional ultrasonography has become the more accepted method for the assessment of thyroid volume (US-TV). The aims of this study were (1) to estimate the preoperative thyroid volume in patients undergoing minimally invasive total thyroidectomy using a mathematical formula and (2) to verify its validity by comparing it with the postsurgical TV (PS-TV). MATERIALS ANDMETHOD:
In 53 patients who underwent minimally invasive total thyroidectomy (from January 2003 to December 2007), US-TV, obtained by ellipsoid volume formula, was compared to PS-TV determined by the Archimedes' principle. A mathematical formula able to predict the TV from the US-TV was applied in 34 cases in the last 2 years.RESULTS:
Mean US-TV (14.4 +/- 5.9 ml) was significantly lower than mean PS-TV (21.7 +/- 10.3 ml). This underestimation was related to gland multinodularity and/or nodular involvement of the isthmus. A mathematical formula to reduce US-TV underestimation and predict the real TV was developed using a linear model. Mean predicted TV (16.8 +/- 3.7 ml) perfectly matched mean PS-TV, underestimating PS-TV in 19% of cases. We verified the accuracy of this mathematical model in patients' eligibility for minimally invasive total thyroidectomy, and we demonstrated that a predicted TV <25 ml was confirmed post-surgery in 94% of cases.CONCLUSIONS:
We demonstrated that using a linear model, it is possible to predict from US the PS-TV with high accuracy. In fact, the mean predicted TV perfectly matched the mean PS-TV in all cases. In particular, the percentage of cases in which the predicted TV perfectly matched the PS-TV increases from 23%, estimated by US, to 43%. Moreover, the percentage of TV underestimation was reduced from 77% to 19%, as well as the range of the disagreement from up to 200% to 80%. This study shows that two-dimensional US can provide the accurate estimation of thyroid volume but that it can be improved by a mathematical model. This may contribute to a more appropriate surgical management of thyroid diseases.
Texto completo:
1
Coleções:
01-internacional
Temas:
Geral
/
Tipos_de_cancer
/
Outros_tipos
Base de dados:
MEDLINE
Assunto principal:
Glândula Tireoide
/
Tireoidectomia
/
Neoplasias da Glândula Tireoide
/
Nódulo da Glândula Tireoide
/
Procedimentos Cirúrgicos Minimamente Invasivos
/
Bócio Nodular
/
Hipertireoidismo
Tipo de estudo:
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Langenbecks Arch Surg
Ano de publicação:
2008
Tipo de documento:
Article
País de afiliação:
Itália