Your browser doesn't support javascript.
loading
The biomechanical performance of bone block and soft-tissue posterior cruciate ligament graft fixation with interference screw and cross-pin techniques.
Lim, Hong Chul; Bae, Ji Hoon; Wang, Joon Ho; Bae, Tae Soo; Kim, Cheol Woong; Hwang, Jin Ho; Yoon, Ji Yeol.
Afiliação
  • Lim HC; Department of Orthopaedic Surgery, Korea University College of Medicine, Guro Hospital, Seoul, South Korea.
Arthroscopy ; 25(3): 250-6, 2009 Mar.
Article em En | MEDLINE | ID: mdl-19245986
PURPOSE: The purpose of this study was to evaluate the biomechanical properties of 4 different graft fixation constructs on the tibial side of the posterior cruciate ligament with reconstruction by use of an Achilles tendon graft. METHODS: Biomechanical testing of 4 different fixation techniques was performed on 20 human cadaveric tibias and Achilles tendons. Cross-pin fixation with bone blocks (group A), interference screw fixation with bone blocks (group B), cross-pin fixation of soft tissue with backup fixation (group C), and interference screw fixation of soft tissue with backup fixation (group D) were tested. The tibia-graft fixation complex was cyclically loaded between 50 N and 250 N at 1 Hz for 1,000 cycles. After cycling, the amount of graft displacement was determined by measuring the change in grip-to-grip distance. The complex was then loaded to failure at 1 mm/s, and maximum failure load, stiffness, and mode of failure were determined. RESULTS: Group C had a higher maximum failure load and stiffness than groups A and B (P < .05 and P < .001, respectively) but poor results for displacement (P < .05 and P < .05, respectively). The failure modes were bone block fracture, graft laceration, or cross-pin fracture in the cross-pin groups and graft pullout in the interference screw groups. CONCLUSIONS: Our study suggests that maximum failure load and stiffness of hybrid fixation for Achilles tendon graft are comparable to those of both single calcaneal bone plug fixation methods that we studied. However, tendon graft displacement was significantly greater regardless of fixation method when compared with bone plug fixation. CLINICAL RELEVANCE: Hybrid fixation for soft-tissue graft on the tibial fixation site provides comparable biomechanical properties of bone-to-bone fixation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Tíbia / Fenômenos Biomecânicos / Ligamento Cruzado Posterior / Procedimentos de Cirurgia Plástica Limite: Adult / Humans / Middle aged Idioma: En Revista: Arthroscopy Assunto da revista: ORTOPEDIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Tíbia / Fenômenos Biomecânicos / Ligamento Cruzado Posterior / Procedimentos de Cirurgia Plástica Limite: Adult / Humans / Middle aged Idioma: En Revista: Arthroscopy Assunto da revista: ORTOPEDIA Ano de publicação: 2009 Tipo de documento: Article País de afiliação: Coréia do Sul