Your browser doesn't support javascript.
loading
Intravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.
He, Yong; Maehara, Akiko; Mintz, Gary S; Bharaj, Harpreet; Castellanos, Celia; Kesanakurthy, Srinivas; Wu, Xiaofan; Guo, Ning; Choi, So-Yeon; Leon, Martin B; Stone, Gregg W; Mehran, Roxana; Rabbani, Leroy E; Moses, Jeffrey W.
Afiliação
  • He Y; Cardiovascular Research Foundation, Columbia University Medical Center-New York Presbyterian Hospital, New York, NY, USA.
Am J Cardiol ; 105(9): 1272-5, 2010 May 01.
Article em En | MEDLINE | ID: mdl-20403478
It is not clear whether the thin struts and different alloy of a cobalt chromium stent will cause greater acute stent recoil compared to conventional stainless steel stents. We used postintervention intravascular ultrasound (IVUS) examinations to study 99 patients with 116 stented lesions: 61 Xience/Promus stents (cobalt chromium stent group) and 27 Taxus Liberté and 28 Cypher stents (stainless steel stent group). The IVUS images were obtained before and immediately after stent implantation with only the stent-delivery balloon. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was the measure of acute stent recoil and expansion. The baseline patient characteristics, lesion morphology, and procedural details were comparable between the 2 groups. The ratio of the IVUS-measured to manufacturer-predicted stent diameter and area was 0.74 versus 0.73 (p = 0.57) and 0.63 versus 0.63 (p = 0.69), respectively, for the cobalt chromium and stainless steel stents. In conclusion, the acute performance of Xience/Promus was similar to that of previous stainless steel stents, and the thinner cobalt chromium metallic platform did not compromise the radial strength of the stent.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Aço Inoxidável / Angioplastia Coronária com Balão / Ligas de Cromo / Ultrassonografia de Intervenção / Materiais Revestidos Biocompatíveis / Estenose Coronária / Stents Farmacológicos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Am J Cardiol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Aço Inoxidável / Angioplastia Coronária com Balão / Ligas de Cromo / Ultrassonografia de Intervenção / Materiais Revestidos Biocompatíveis / Estenose Coronária / Stents Farmacológicos Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male Idioma: En Revista: Am J Cardiol Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos