Your browser doesn't support javascript.
loading
Dose exposure in the ITALUNG trial of lung cancer screening with low-dose CT.
Mascalchi, M; Mazzoni, L N; Falchini, M; Belli, G; Picozzi, G; Merlini, V; Vella, A; Diciotti, S; Falaschi, F; Lopes Pegna, A; Paci, E.
Afiliação
  • Mascalchi M; Radiodiagnostic Section, Department of Clinical Physiopathology, University of Florence, Florence, Italy. m.mascalchi@dfc.unifi.it
Br J Radiol ; 85(1016): 1134-9, 2012 Aug.
Article em En | MEDLINE | ID: mdl-21976631
ABSTRACT
Few data are available on the effective dose received by participants in lung cancer screening programmes with low-dose CT (LDCT). We report the collective effective dose delivered to 1406 current or former smokers enrolled in the ITALUNG trial who completed 4 annual LDCT examinations and related further investigations including follow-up LDCT, 2-[(18)F]flu-2-deoxy-d-glucose positron emission tomography (FDG-PET) or CT-guided fine needle aspiration biopsy (FNAB). Using the air CT dose index and Monte Carlo simulations on an anthropomorphic phantom, the whole-body effective dose associated with LDCT was determined for the eight CT scanners used in the trial. A value of 7 mSv was assigned to FDG-PET while the measured mean effective dose of CT-guided FNAB was 1.5 mSv. The mean collective effective dose in the 1406 subjects ranged between 8.75 and 9.36 Sv and the mean effective dose to the single subject over 4 years was between 6.2 and 6.8 mSv (range 1.7-21.5 mSv) according to the cranial-caudal length of the LDCT volume. 77.4% of the dose was owing to annual LDCT and 22.6% to further investigations. Considering the nominal risk coefficients for stochastic effects after exposure to low-dose radiation according to the National Radiological Protection Board, International Commission on Radiological Protection (ICRP) 60, ICRP103 and Biological Effects of Ionizing Radiation VII, the mean number of radiation-induced cancers ranged between 0.12 and 0.33 per 1000 subjects. The individual effective dose to participants in a 4-year lung cancer screening programme with annual LDCT is very low and about one-third of the effective dose that is associated with natural background radiation and diagnostic radiology in the same time period.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Pulmao Base de dados: MEDLINE Assunto principal: Detecção Precoce de Câncer / Neoplasias Pulmonares Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Radiol Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Pulmao Base de dados: MEDLINE Assunto principal: Detecção Precoce de Câncer / Neoplasias Pulmonares Tipo de estudo: Clinical_trials / Diagnostic_studies / Etiology_studies / Risk_factors_studies / Screening_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Br J Radiol Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Itália