Your browser doesn't support javascript.
loading
Classification of breast lesions pre-contrast injection using water resonance lineshape analysis.
NMR Biomed ; 26(5): 569-77, 2013 May.
Article em En | MEDLINE | ID: mdl-23165988
Inhomogeneously broadened, non-Lorentzian water resonances have been observed in small image voxels of breast tissue. The non-Lorentzian components of the water resonance are probably produced by bulk magnetic susceptibility shifts caused by dense, deoxygenated tumor blood vessels (the 'blood oxygenation level-dependent' effect), but can also be produced by other characteristics of local anatomy and physiology, including calcifications and interfaces between different types of tissue. Here, we tested the hypothesis that the detection of non-Lorentzian components of the water resonance with high spectral and spatial resolution (HiSS) MRI allows the classification of breast lesions without the need to inject contrast agent. Eighteen malignant lesions and nine benign lesions were imaged with HiSS MRI at 1.5 T. A new algorithm was developed to detect non-Lorentzian (or off-peak) components of the water resonance. After a Lorentzian fit had been subtracted from the data, the largest peak in the residual spectrum in each voxel was identified as the major off-peak component of the water resonance. The difference in frequency between these off-peak components and the main water peaks, and their amplitudes, were measured in malignant lesions, benign lesions and breast fibroglandular tissue. Off-peak component frequencies were significantly different between malignant and benign lesions (p < 0.001). Receiver operating characteristic (ROC) analysis was used to assess the diagnostic performance of HiSS off-peak component analysis compared with dynamic contrast-enhanced (DCE) MRI parameters. The areas under the ROC curves for the 'DCE rapid uptake fraction', 'DCE washout fraction', 'off-peak component amplitude' and 'off-peak component frequency' were 0.75, 0.83, 0.50 and 0.86, respectively. These results suggest that water resonance lineshape analysis performs well in the classification of breast lesions without contrast injection and could improve the diagnostic accuracy of clinical breast MR examinations. In addition, this approach may provide an alternative to DCE MRI in women who are at risk for adverse reactions to contrast media.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Mama / Neoplasias da Mama / Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos