ABSTRACT
OBJECTIVE:
To assess the effects of length of continuous femoral catheter on blockade of femoral nerve, lateral femoral cutaneous nerve and obturator nerve.METHODS:
In the study, 70 patients with American Association of Anesthesiologist grades I-II undergoing total knee arthroplasty were randomly divided into three groups, femoral nerve catheters were inserted 5 cm, 10 cm or 20 cm with assistance of a nerve stimulator, patient-controlled analgesia pumps were connected after load of 30 mL 0.3% ropivacaine via the catheters. Sensory blockade of the femoral nerve, lateral femoral cutaneous nerve and obturator nerve were recorded at 24 h postoperatively. Visual analog scale (VAS) pain scores during rest and motion were recorded at 24 h and 48 h postoperatively.RESULTS:
The blockade effect of lateral femoral nerve in the 20 cm group was the best. There was no significant difference in sensory blockade between the 5 cm group and the 10 cm group. There was no significant difference in VAS score among the three groups.CONCLUSION:
When continuous femoral nerve block is used for postoperative analgesia after total knee arthroplasty surgery, the catheters that are inserted 5 cm, 10 cm or 20 cm could provide similar and satisfying analgesia effect.
Buscar no Google
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Cateterismo
/
Nervo Femoral
/
Bloqueio Nervoso
Tipo de estudo:
Clinical_trials
Limite:
Humans
Idioma:
Zh
Revista:
Beijing Da Xue Xue Bao Yi Xue Ban
Assunto da revista:
MEDICINA
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
China