Elephant trunk in a small-calibre true lumen for chronic aortic dissection: cause of haemolytic anaemia?
Araki, Haruna; Kitamura, Tadashi; Horai, Tetsuya; Shibata, Ko; Miyaji, Kagami.
Afiliação
  • Araki H; Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan haruna.araki0401@gmail.com.
  • Kitamura T; Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.
  • Horai T; Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.
  • Shibata K; NTT Medical Center Tokyo, Tokyo, Japan.
  • Miyaji K; Department of Cardiovascular Surgery, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.
Interact Cardiovasc Thorac Surg ; 19(6): 1065-7, 2014 Dec.
Article em En | MEDLINE | ID: mdl-25228241
OBJECTIVES: The elephant trunk technique for aortic dissection is useful for reducing false lumen pressure; however, a folded vascular prosthesis inside the aorta can cause haemolysis. The purpose of this study was to investigate whether an elephant trunk in a small-calibre lumen can cause haemolysis. METHODS: Inpatient and outpatient records were retrospectively reviewed. RESULTS: Two cases of haemolytic anaemia after aortic surgery using the elephant trunk technique were identified from 2011 to 2013. A 64-year-old man, who underwent graft replacement of the ascending aorta for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta and moderate aortic regurgitation. A two-stage surgery was scheduled. Total arch replacement with an elephant trunk in the true lumen and concomitant aortic valve replacement were performed. Postoperatively, he developed severe haemolytic anaemia because of the folded elephant trunk. The anaemia improved after the second surgery, including graft replacement of the descending aorta. Similarly, a 61-year-old man, who underwent total arch replacement for acute Stanford type A aortic dissection, presented with enlargement of the chronic dissection of the descending aorta. Graft replacement of the descending aorta with an elephant trunk inserted into the true lumen was performed. The patient postoperatively developed haemolytic anaemia because of the folded elephant trunk, which improved after additional stent grafting into the elephant trunk. CONCLUSIONS: A folded elephant trunk in a small-calibre lumen can cause haemolysis. Therefore, inserting an elephant trunk in a small-calibre true lumen during surgery for chronic aortic dissection should be avoided.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Prótese Vascular / Implante de Prótese Vascular / Anemia Hemolítica / Dissecção Aórtica Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Interact cardiovasc thorac surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Prótese Vascular / Implante de Prótese Vascular / Anemia Hemolítica / Dissecção Aórtica Tipo de estudo: Diagnostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Interact cardiovasc thorac surg Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Japão