Your browser doesn't support javascript.
loading
Reliability and validity in measurement of true humeral retroversion by a three-dimensional cylinder fitting method.
Saka, Masayuki; Yamauchi, Hiroki; Hoshi, Kenji; Yoshioka, Toru; Hamada, Hidetoshi; Gamada, Kazuyoshi.
Afiliação
  • Saka M; Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan. Electronic address: sakamasayuki.25@gmail.com.
  • Yamauchi H; Department of Rehabilitation, Kameda Medical Center, Chiba, Japan.
  • Hoshi K; Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan.
  • Yoshioka T; Department of Orthopaedic Surgery, Saka Midorii Hospital, Hiroshima, Japan.
  • Hamada H; Department of Orthopaedic Surgery, Hamawaki Orthopaedic Hospital, Hiroshima, Japan.
  • Gamada K; Graduate School of Medical Technology and Health Welfare Sciences, Hiroshima International University, Hiroshima, Japan.
J Shoulder Elbow Surg ; 24(5): 809-13, 2015 May.
Article em En | MEDLINE | ID: mdl-25457190
HYPOTHESIS AND BACKGROUND: Humeral retroversion is defined as the orientation of the humeral head relative to the distal humerus. Because none of the previous methods used to measure humeral retroversion strictly follow this definition, values obtained by these techniques vary and may be biased by morphologic variations of the humerus. The purpose of this study was 2-fold: to validate a method to define the axis of the distal humerus with a virtual cylinder and to establish the reliability of 3-dimensional (3D) measurement of humeral retroversion by this cylinder fitting method. METHODS: Humeral retroversion in 14 baseball players (28 humeri) was measured by the 3D cylinder fitting method. The root mean square error was calculated to compare values obtained by a single tester and by 2 different testers using the embedded coordinate system. To establish the reliability, intraclass correlation coefficient (ICC) and precision (standard error of measurement [SEM]) were calculated. RESULTS: The root mean square errors for the humeral coordinate system were <1.0 mm/1.0° for comparison of all translations/rotations obtained by a single tester and <1.0 mm/2.0° for comparison obtained by 2 different testers. Assessment of reliability and precision of the 3D measurement of retroversion yielded an intratester ICC of 0.99 (SEM, 1.0°) and intertester ICC of 0.96 (SEM, 2.8°). DISCUSSION AND CONCLUSION: The error in measurements obtained by a distal humerus cylinder fitting method was small enough not to affect retroversion measurement. The 3D measurement of retroversion by this method provides excellent intratester and intertester reliability.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Simulação por Computador / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Cabeça do Úmero / Retroversão Óssea Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Simulação por Computador / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Cabeça do Úmero / Retroversão Óssea Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Male Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2015 Tipo de documento: Article