Your browser doesn't support javascript.
loading
Ultrasonic wave properties of human bone marrow in the femur and tibia.
Kawasaki, Satoshi; Ueda, Ryohei; Hasegawa, Akihiko; Fujita, Akifumi; Mihata, Teruhisa; Matsukawa, Mami; Neo, Masashi.
Afiliação
  • Kawasaki S; Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan.
  • Ueda R; Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan.
  • Hasegawa A; Department of Orthopedic Surgery, Daiichi Towakai Hospital, 2-17, Miyano-cho, Takatsuki, Osaka 569-0081, Japan.
  • Fujita A; Department of Orthopedic Surgery, Daiichi Towakai Hospital, 2-17, Miyano-cho, Takatsuki, Osaka 569-0081, Japan.
  • Mihata T; Department of Orthopedic Surgery, Osaka Medical College, 2-7, Daigaku-machi, Takatsuki, Osaka 569-8686, Japan k11028349@gmail.com, bml1110.doshisha@gmail.com, youandmeco@yahoo.co.jp, akifumifujita@yahoo.co.jp, tmihata@yahoo.co.jp, mmatsuka@mail.doshisha.ac.jp, neo@poh.osaka-med.ac.jp.
  • Matsukawa M; Laboratory of Ultrasonic Electronics, Doshisha University, 1-3 Tatara-Miyakodani, Kyotanabe, Kyoto 610-0321, Japan.
  • Neo M; Department of Orthopedic Surgery, Osaka Medical College, 2-7, Daigaku-machi, Takatsuki, Osaka 569-8686, Japan k11028349@gmail.com, bml1110.doshisha@gmail.com, youandmeco@yahoo.co.jp, akifumifujita@yahoo.co.jp, tmihata@yahoo.co.jp, mmatsuka@mail.doshisha.ac.jp, neo@poh.osaka-med.ac.jp.
J Acoust Soc Am ; 138(1): EL83-7, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26233067
ABSTRACT
Ultrasonic wave properties of human bone marrow obtained in the femur and tibia were measured using an ultrasound pulse technique. The measured frequency range was 4-10 MHz, and the temperature range was 30 °C-40 °C. The sound velocity was 1410 m/s, and the attenuation coefficient was 4.4 dB/cm at 36 °C (10 MHz). These values decreased with temperature. Site dependence and individual differences in elderly human bone marrow were negligible. The slopes of the attenuation coefficient were estimated by a power law. The values of the exponent n were 2.0 (30 °C-38 °C) and 2.3 (40 °C).
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Tíbia / Medula Óssea / Fêmur / Ondas Ultrassônicas Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Tíbia / Medula Óssea / Fêmur / Ondas Ultrassônicas Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão