Your browser doesn't support javascript.
loading
Rapid colorimetric sensing platform for the detection of Listeria monocytogenes foodborne pathogen.
Alhogail, Sahar; Suaifan, Ghadeer A R Y; Zourob, Mohammed.
Afiliação
  • Alhogail S; Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia.
  • Suaifan GARY; Department of Pharmaceutical Sciences, Faculty of Pharmacy, The University of Jordan, Amman 11942, Jordan.
  • Zourob M; Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi Road, Riyadh 11533, Saudi Arabia; King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh 12713, Saudi Arabia. Electronic address: mzourob@alfaisal.edu.
Biosens Bioelectron ; 86: 1061-1066, 2016 Dec 15.
Article em En | MEDLINE | ID: mdl-27543841
ABSTRACT
Listeria monocytogenes is a serious cause of human foodborne infections worldwide, which needs spending billions of dollars for inspection of bacterial contamination in food every year. Therefore, there is an urgent need for rapid, in-field and cost effective detection techniques. In this study, rapid, low-cost and simple colorimetric assay was developed using magnetic nanoparticles for the detection of listeria bacteria. The protease from the listeria bacteria was detected using D-amino acid substrate. D-amino acid substrate was linked to the carboxylic acid on the magnetic nanoparticles using EDC/NHS chemistry. The cysteine residue at the C-terminal of the substrate was used for the self-assembled monolayer formation on the gold sensor surface, which in turn the black magnetic nanobeads will mask the golden color. The color will change from black to golden color upon the cleavage of the specific peptide sequence by the Listeria protease. The sensor was tested with serial dilutions of Listeria bacteria. It was found that the appearance of the gold surface area is proportional to the bacterial concentrations in CFU/ml. The lowest detection limit of the developed sensor for Listeria was found to be 2.17×10(2) colony forming unit/ml (CFU/ml). The specificity of the biosensor was tested against four different foodborne associated bacteria (Escherichia coli, Salmonella, Shigella flexnerii and Staphylococcus aureus). Finally, the sensor was tested with artificially spiked whole milk and ground meat spiked with listeria.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Peptídeo Hidrolases / Contaminação de Alimentos / Colorimetria / Análise de Alimentos / Microbiologia de Alimentos / Listeria monocytogenes Tipo de estudo: Clinical_trials / Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Arábia Saudita

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Peptídeo Hidrolases / Contaminação de Alimentos / Colorimetria / Análise de Alimentos / Microbiologia de Alimentos / Listeria monocytogenes Tipo de estudo: Clinical_trials / Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Arábia Saudita