Your browser doesn't support javascript.
loading
A hybrid multibreath wash-in wash-out lung function quantification scheme in human subjects using hyperpolarized 3 He MRI for simultaneous assessment of specific ventilation, alveolar oxygen tension, oxygen uptake, and air trapping.
Hamedani, Hooman; Kadlecek, Stephen; Xin, Yi; Siddiqui, Sarmad; Gatens, Heather; Naji, Joseph; Ishii, Masaru; Cereda, Maurizio; Rossman, Milton; Rizi, Rahim.
Afiliação
  • Hamedani H; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Kadlecek S; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Xin Y; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Siddiqui S; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Gatens H; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Naji J; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Ishii M; Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Cereda M; Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins University, Baltimore, Maryland, USA.
  • Rossman M; Department of Anesthesiology and Critical Care, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
  • Rizi R; Pulmonary, Allergy and Critical Care Division, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Magn Reson Med ; 78(2): 611-624, 2017 08.
Article em En | MEDLINE | ID: mdl-27734519
ABSTRACT

PURPOSE:

To present a method for simultaneous acquisition of alveolar oxygen tension (PA O2 ), specific ventilation (SV), and apparent diffusion coefficient (ADC) of hyperpolarized (HP) gas in the human lung, allowing reinterpretation of the PA O2 and SV maps to produce a map of oxygen uptake (R).

METHOD:

An imaging scheme was designed with a series of identical normoxic HP gas wash-in breaths to measure ADC, SV, PA O2 , and R in less than 2 min. Signal dynamics were fit to an iterative recursive model that regionally solved for these parameters. This measurement was successfully performed in 12 subjects classified in three healthy, smoker, and chronic obstructive pulmonary disease (COPD) cohorts.

RESULTS:

The overall whole lung ADC, SV, PA O2 , and R in healthy, smoker, and COPD subjects was 0.20 ± 0.03 cm2 /s, 0.39 ± 0.06,113 ± 2 Torr, and 1.55 ± 0.35 Torr/s, respectively, in healthy subjects; 0.21 ± 0.03 cm2 /s, 0.33 ± 0.06, 115.9 ± 4 Torr, and 0.97 ± 0.2 Torr/s, respectively, in smokers; and 0.25 ± 0.06 cm2 /s, 0.23 ± 0.08, 114.8 ± 6.0Torr, and 0.94 ± 0.12 Torr/s, respectively, in subjects with COPD. Hetrogeneity of SV, PA O2 , and R were indicators of both smoking-related changes and disease, and the severity of the disease correlated with the degree of this heterogeneity. Subjects with symptoms showed reduced oxygen uptake and specific ventilation.

CONCLUSION:

High-resolution, nearly coregistered and quantitative measures of lung function and structure were obtained with less than 1 L of HP gas. This hybrid multibreath technique produced measures of lung function that revealed clear differences among the cohorts and subjects and were confirmed by correlations with global lung measurements. Magn Reson Med 78611-624, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Oxigênio / Alvéolos Pulmonares / Trítio / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Oxigênio / Alvéolos Pulmonares / Trítio / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos