Role of 18F-fluorodeoxyglucose Positron Emission Tomography in the Monitoring of Inflammatory Activity in Crohn's Disease.
Inflamm Bowel Dis
; 22(11): 2619-2629, 2016 11.
Article
em En
| MEDLINE
| ID: mdl-27753695
BACKGROUND: Fluorine-fluorodeoxyglucose positron emission tomography (F-FDG PET) has recently attracted interest for the measurement of disease activity in Crohn's disease (CD). The aim of this study was to assess the utility of FDG-PET as a marker of progression of inflammatory activity and its response to treatment in patients with CD. METHODS: Twenty-two patients with active CD were recruited prospectively to undergo FDG-PET scanning at 2 time points. All 22 index scans were used to assess sensitivity and specificity against a reference standard magnetic resonance imaging measure. Correlations with clinicopathological markers of severity (Harvey-Bradshaw Index, C-reactive protein, and calprotectin) were also performed. Of note, 17/22 patients participated in the longitudinal component and underwent scanning before and 12 weeks after the initiation of anti-tumor necrosis factor alpha therapy. Patients were subcategorized on the basis of a clinically significant response, and responsiveness of the PET measures was assessed using previously described indices. Of note, 5/22 patients took part in the test-retest component of the study and underwent scanning twice within a target interval of 1 week, to assess the reproducibility of the PET measures. RESULTS: The sensitivity and specificity of F-FDG PET were 88% and 70%, respectively. Standardized uptake value (SUV)-related PET measures correlated significantly both with C-reactive protein and Harvey-Bradshaw Index in cross-sectional and longitudinal analyses. (G)SUVMAX and (G)SUVMEAN demonstrated favorable responsiveness and reliability characteristics (responsiveness ratio of Guyatt >0.80 and % variability <20%) compared with volume-dependent FDG-PET measures. A proportion of the FDG signal (10%-30%) was found to originate from the lumen of diseased segments. CONCLUSIONS: F-FDG PET may be useful for longitudinal monitoring of inflammatory activity in CD.
Buscar no Google
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Doença de Crohn
/
Compostos Radiofarmacêuticos
/
Fluordesoxiglucose F18
/
Tomografia por Emissão de Pósitrons
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
Limite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Revista:
Inflamm Bowel Dis
Assunto da revista:
GASTROENTEROLOGIA
Ano de publicação:
2016
Tipo de documento:
Article