Your browser doesn't support javascript.
loading
Effects of a novel tungsten-impregnated rubber neck shield on the quality of cerebral images acquired using 15O-labeled gas.
Wagatsuma, Kei; Oda, Keiichi; Miwa, Kenta; Inaji, Motoki; Sakata, Muneyuki; Toyohara, Jun; Ishiwata, Kiichi; Sasaki, Masayuki; Ishii, Kenji.
Afiliação
  • Wagatsuma K; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-1, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
  • Oda K; Department of Health Sciences, Graduate School of Medical Science, Kyushu University, Fukuoka, Japan.
  • Miwa K; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-1, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
  • Inaji M; Faculty of Health Science, Hokkaido University of Science, Sapporo, Japan.
  • Sakata M; School of Health Science, International University of Health and Welfare, Ohtawara, Japan.
  • Toyohara J; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-1, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
  • Ishiwata K; Department of Neurosurgery, Tokyo Medical and Dental University, Tokyo, Japan.
  • Sasaki M; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-1, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
  • Ishii K; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, 35-1, Sakae-cho, Itabashi-ku, Tokyo, 173-0015, Japan.
Radiol Phys Technol ; 10(4): 422-430, 2017 Dec.
Article em En | MEDLINE | ID: mdl-28823084
ABSTRACT
The present study aimed to validate the effects of a novel tungsten-impregnated rubber neck shield on the quality of phantom and clinical 15O-labeled gas positron emission tomography (PET) images. Images were acquired in the presence or absence of a neck shield from a cylindrical phantom containing [15O]H2O (phantom study) and from three individuals using [15O]CO2, [15O]O2 and [15O]CO gas (clinical study). Data were acquired in three-dimensional (3D) mode using a Discovery PET/CT 710. Values for cerebral blood flow, cerebral blood volume, oxygen extraction fraction, and cerebral metabolic rate of oxygen with and without the neck shield were calculated from 15O-labeled gas images. Arterial radioactivity and count characteristics were evaluated in the phantom and clinical studies. The coefficient of variance (CV) for the phantom study and the standard deviation (SD) for functional images were also analyzed. The neck shield decreased the random count rates by 25-59% in the phantom and clinical studies. The noise equivalent count rate (NECR) increased by 44-66% in the phantom and clinical studies. Random count rates and NECR in [15O]CO2 images significantly differed with and without the neck shield. The improvement in visual and physical image quality with the neck shield was not observed in the phantom and clinical studies. The novel neck shield reduced random count rate and improved NECR in a 3D PET study using 15O-labeled gas. The image quality with the neck shield was similar to that without the neck shield.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Radioisótopos de Oxigênio / Borracha / Tungstênio / Processamento de Imagem Assistida por Computador / Encéfalo / Imagens de Fantasmas / Pescoço Limite: Humans Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Temas: Agentes_cancerigenos Base de dados: MEDLINE Assunto principal: Radioisótopos de Oxigênio / Borracha / Tungstênio / Processamento de Imagem Assistida por Computador / Encéfalo / Imagens de Fantasmas / Pescoço Limite: Humans Idioma: En Revista: Radiol Phys Technol Assunto da revista: BIOFISICA / RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Japão