[Clinical observation of visual quality after the individual implantation of intraocular lens guided by corneal Q value].
Zhonghua Yan Ke Za Zhi
; 53(11): 814-820, 2017 Nov 11.
Article
em Zh
| MEDLINE
| ID: mdl-29141385
Objective: To describe the feasibility of individual IOL implantation guided by corneal Q value and observe patients postoperative visual quality under different residual spherical aberration. Methods: Prospective study. One hundred and twenty cases (171 eyes)cataract patients in our hospital were selected for the individual implantation of intraocular lens guided by corneal Q value which obtained by Oberscan before operation. Based on spherical aberration calculated by corneal Q value, choose appropriate IOL personalitily to make postoperative whole eye surface aberration +0.1 µm (group of positive spherical aberration) or 0 µm (group of zero spherical aberration). To observe spherical aberration, the uncorrected visual acuity, best corrected visual acuity and contrast sensitivity (including no glare and glare) 1 month and 3 months after surgery. Dates were analyzed with one-way ANOVA and LSD method for multiple comparisons between groups. Results: Spherical aberration after operation: group of positive spherical aberration: (0.111±0.023)µm, group of zero spherical aberration: (0.020±0.019)µm, control group: (0.299±0.073)µm. At 1 months and 3 months, uncorrected visual acuity, and corrected visual acuity were not statistically different between groups (t=0.474, 1.607, P>0.05). Contrast sensitivity (including no glare and glare) 3 months after surgery display: at whole space frequency, the group of positive spherical aberration(reserved +0.1 µm spherical aberration) contrast sensitivity is better than that of the group of zero spherical aberration(reserved 0.0 µm spherical aberration) and the control group(F=32.885, 35.493, 19.969, 20.572,P<0.05). The group of zero spherical aberration is better than control group at space frequency of 3 and 6 c/d(F=6.506, 7.521, P<0.05). Conclusions: The individual implantation of introcular lens guided by corneal Q value is feasible. + 0.1 µm spherical aberration after surgery can achieve the best contrast sensitivity and stereo vision, and 0 spherical aberration after surgery can improve the postoperative contrast sensitivity and stereo vision than a traditional method, but its advantage mainly embodies in the middle and lower spatial frequency. (Chin J Ophthalmol, 2017, 53: 814-820).
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Extração de Catarata
/
Acuidade Visual
/
Facoemulsificação
/
Implante de Lente Intraocular
/
Lentes Intraoculares
Tipo de estudo:
Observational_studies
Limite:
Humans
Idioma:
Zh
Revista:
Zhonghua Yan Ke Za Zhi
Ano de publicação:
2017
Tipo de documento:
Article
País de afiliação:
China