Your browser doesn't support javascript.
loading
Effect of image registration on 3D absorbed dose calculations in 177Lu-DOTATOC peptide receptor radionuclide therapy.
Grassi, Elisa; Fioroni, Federica; Berenato, Salvatore; Patterson, Nick; Ferri, Valentina; Braglia, Luca; Filice, Angelina; Versari, Annibale; Iori, Mauro; Spezi, Emiliano.
Afiliação
  • Grassi E; Medical Physics Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy. Electronic address: elisa.grassi@ausl.re.it.
  • Fioroni F; Medical Physics Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Berenato S; School of Engineering, Cardiff University, Cardiff, Wales, UK.
  • Patterson N; Department of Medical Physics, Velindre Cancer Centre, Cardiff, Wales, UK.
  • Ferri V; Medical Physics Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Braglia L; Unità Studi Clinici e Statistica, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Filice A; Nuclear Medicine Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Versari A; Nuclear Medicine Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Iori M; Medical Physics Unit, Azienda Unità Sanitaria Locale - IRCCS di Reggio Emilia, Reggio Emilia, Italy.
  • Spezi E; Department of Medical Physics, Velindre Cancer Centre, Cardiff, Wales, UK; School of Engineering, Cardiff University, Cardiff, Wales, UK.
Phys Med ; 45: 177-185, 2018 Jan.
Article em En | MEDLINE | ID: mdl-29472084
ABSTRACT
Peptide receptor radionuclide therapy (PRRT) is an effective MRT (molecular radiotherapy) treatment, which consists of multiple administrations of a radiopharmaceutical labelled with 177Lu or 90Y. Through sequential functional imaging a patient specific 3D dosimetry can be derived. Multiple scans should be previously co-registered to allow accurate absorbed dose calculations. The purpose of this study is to evaluate the impact of image registration algorithms on 3D absorbed dose calculation. A cohort of patients was extracted from the database of a clinical trial in PRRT. They were administered with a single administration of 177Lu-DOTATOC. All patients underwent 5 SPECT/CT sequential scans at 1 h, 4 h, 24 h, 40 h, 70 h post-injection that were subsequently registered using rigid and deformable algorithms. A similarity index was calculated to compare rigid and deformable registration algorithms. 3D absorbed dose calculation was carried out with the Raydose Monte Carlo code. The similarity analysis demonstrated the superiority of the deformable registrations (p < .001). Average absorbed dose to the kidneys calculated using rigid image registration was consistently lower than the average absorbed dose calculated using the deformable algorithm (90% of cases), with percentage differences in the range [-19; +4]%. Absorbed dose to lesions were also consistently lower (90% of cases) when calculated with rigid image registration with absorbed dose differences in the range [-67.2; 100.7]%. Deformable image registration had a significant role in calculating 3D absorbed dose to organs or lesions with volumes smaller than 100 mL. Image based 3D dosimetry for 177Lu-DOTATOC PRRT is significantly affected by the type of algorithm used to register sequential SPECT/CT scans.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Radiometria / Dosagem Radioterapêutica / Planejamento da Radioterapia Assistida por Computador / Octreotida / Tomografia Computadorizada por Raios X / Tomografia Computadorizada de Emissão de Fóton Único Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Radiometria / Dosagem Radioterapêutica / Planejamento da Radioterapia Assistida por Computador / Octreotida / Tomografia Computadorizada por Raios X / Tomografia Computadorizada de Emissão de Fóton Único Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: Phys Med Assunto da revista: BIOFISICA / BIOLOGIA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article