Chemical shift imaging with in-phase and opposed-phase sequences at 3 T: what is the optimal threshold, measurement method, and diagnostic accuracy for characterizing marrow signal abnormalities?
Kumar, Neil M; Ahlawat, Shivani; Fayad, Laura M.
Afiliação
  • Kumar NM; Dakota Radiology, 2929 5th St #100, Rapid City, SD, 57701, USA. nmk2008@gmail.com.
  • Ahlawat S; The Russell H. Morgan Department of Radiology & Radiological Science, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD, 21287, USA. nmk2008@gmail.com.
  • Fayad LM; The Russell H. Morgan Department of Radiology & Radiological Science, The Johns Hopkins Medical Institutions, 600 North Wolfe Street, Baltimore, MD, 21287, USA.
Skeletal Radiol ; 47(12): 1661-1671, 2018 Dec.
Article em En | MEDLINE | ID: mdl-29936558
ABSTRACT

OBJECTIVE:

To determine the threshold signal drop on 3-T chemical shift imaging (CSI), with in-phase (IP) and opposed-phase (OP) sequences, for accurately identifying bone marrow replacement with 100% sensitivity, and determine a clinically useful measurement method for deriving such a threshold. MATERIALS AND

METHODS:

From a convenience series of 157 MRIs, 36 cases with histologically proven marrow-replacing lesions and 22 sites of red marrow (histologically proven (2) or with minimum 6-month stability) with 3-Tesla CSI were included. Two musculoskeletal radiologists performed two measurement methods (first multiple algorithmic ROIs at the top, middle, and bottom of lesions (M-ROI); second an ROI was drawn where there appeared to be the least opposed-phase signal reduction qualitatively/visually (Q-ROI)). Lesional and red marrow signal change (%,[(IP-OP)signal/IP signal]*100) was determined. Statistical analyses included Student's t test, Cohen's kappa, and receiver operator characteristic curve generation.

RESULTS:

By M-ROI, lesion signal change was - 0.508% (confidence interval (CI) = - 5.5374.521) and 1.348% (CI = - 3.5416.311) for readers 1 and 2. By Q-ROI, lesion signal change was - 11.03% (CI = - 17.01- 5.046) and - 5.657% (CI = - 12.361.048) for readers 1 and 2. For all M-ROI and Q-ROI measurement strategies, signal change between lesional tissue and red marrow was significantly different (p < 0.0001). QROI produced the best composite sensitivities and specificities with a maximized Youden index of 0.955-1. A threshold signal drop of 25% with Q-ROI produced at least 100%/86% sensitivity/specificity for both readers for identifying marrow replacement.

CONCLUSIONS:

For 3-T CSI, a single visually targeted measurement using a 25% threshold is accurate for identifying marrow-replacing lesions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Doenças da Medula Óssea / Neoplasias Ósseas / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Skeletal Radiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Doenças da Medula Óssea / Neoplasias Ósseas / Imageamento por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Skeletal Radiol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos