Your browser doesn't support javascript.
loading
New strategy for the gene mutation identification using surface enhanced Raman spectroscopy (SERS).
Kowalczyk, Agata; Krajczewski, Jan; Kowalik, Artur; Weyher, Jan L; Dziecielewski, Igor; Chlopek, Malgorzata; Gózdz, Stanislaw; Nowicka, Anna M; Kudelski, Andrzej.
Afiliação
  • Kowalczyk A; Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland.
  • Krajczewski J; Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland.
  • Kowalik A; Holy Cross Cancer Center, Stefana Artwinskiego Str. 3, PL 25-734 Kielce, Poland.
  • Weyher JL; Institute of High Pressure Physics of the Polish Academy of Science, Sokolowska 29/37 Str., PL 01-142 Warsaw, Poland.
  • Dziecielewski I; Institute of High Pressure Physics of the Polish Academy of Science, Sokolowska 29/37 Str., PL 01-142 Warsaw, Poland.
  • Chlopek M; Holy Cross Cancer Center, Stefana Artwinskiego Str. 3, PL 25-734 Kielce, Poland.
  • Gózdz S; Holy Cross Cancer Center, Stefana Artwinskiego Str. 3, PL 25-734 Kielce, Poland.
  • Nowicka AM; Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland. Electronic address: anowicka@chem.uw.edu.pl.
  • Kudelski A; Faculty of Chemistry, University of Warsaw, Pasteura 1 Str., PL 02-093 Warsaw, Poland.
Biosens Bioelectron ; 132: 326-332, 2019 May 01.
Article em En | MEDLINE | ID: mdl-30897539
ABSTRACT
An early and accurate diagnosis of a specific DNA mutations has a decisive role for effective treatment. Especially, when an immediate decision on treatment most needs to be made, the rapid and precise confirmation of clinical findings is vital. Herein, we show a new strategy for the gene mutation (BRAF c.1799T>A; p. V600E) identification using highly SERS-active and reproducible SERS substrate (photo-etched GaN covered with a thin layer of sputtered gold) and surface enhanced Raman scattering (SERS) spectroscopy. The detection is based on the conformation change (gauche → trans) of the alkanethiol linker modifying the capture DNA during the hybridization process. The value of the intensity ratio of the ν(C-S) bands of the trans and gauche conformer higher than 1.0 indicated the presence of mutation. The demonstrated new DNA SERS (bio)sensor is characterized by the low detection limit at the level of pg µL-1, wide analytical range from 6.75 pg µL-1 to 67.5 ng µL-1 and high selectivity. The proposed bioactive platforms, based on nanostructured GaN substrates modified with thiolated ssDNA (single stranded DNA) can be successfully used in the analysis of clinical samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Análise Mutacional de DNA / Mutação Puntual / Proteínas Proto-Oncogênicas B-raf Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Análise Mutacional de DNA / Mutação Puntual / Proteínas Proto-Oncogênicas B-raf Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Polônia