Projection resolved optical coherence tomography angiography to distinguish flow signal in retinal angiomatous proliferation from flow artifact.
PLoS One
; 14(5): e0217109, 2019.
Article
em En
| MEDLINE
| ID: mdl-31091288
PURPOSE: To investigate whether hyperreflective foci (HRF) exhibit flow projection artifact on OCTA, and study the efficacy of commercial projection artifact removal software (PAR-OCTA, Optovue, Inc), and a custom projection resolved OCTA (PR-OCTA) in distinguishing artifacts from true flow in retinal angiomatous proliferation (RAP). METHODS: The study included five eyes with HRF representing pigment migration in dry age-related macular degeneration (AMD), five eyes with leaking treatment-naïve RAP, and ten eyes with diabetic hard exudates. We examined flow signal on OCTA cross-sections using PAR, and performed PR-OCTA to study the effect of increasingly stringent projection removal thresholds. Flow signal intensity was analyzed and quantified using imageJ (NIH, Bethesda, MD, USA), by calculating the percentage of red pixels (R) representing flow, compared to green (G) and blue (B) pixels. RESULTS: PAR-OCTA cross sections revealed persistent flow signal in all HRF, including RAP, hard exudates and pigment migration. In RAP, PR-OCTA detected intransigent flow, irrespective of the flow removal threshold. Mean R in the five RAP lesions remained higher than mean G and B at the most stringent PR-OCTA threshold (40.96% vs 29.52 and 29.52%, respectively), denoting persistence of flow. In contrast, increasing the PR-OCTA threshold in pigment migration and hard exudates removed the flow signal, with a statistically significant decrease in mean R with increasing threshold. (p = 0.017 and 0.0029, respectively). CONCLUSION: Commercial PAR-OCTA is not completely effective at removing artifactual flow in hard exudates and HRF related to pigment migration. Custom built PR-OCTA, using a sliding scale of threshold, allowed us to distinguish true flow in RAP from artifactual flow in avascular HRF. Further studies are needed to validate the optimum threshold for projection artifact removal, which would preserve true flow in RAP and the small intraretinal capillaries.
Texto completo:
1
Coleções:
01-internacional
Temas:
Geral
Base de dados:
MEDLINE
Assunto principal:
Vasos Retinianos
/
Neovascularização Retiniana
/
Tomografia de Coerência Óptica
/
Proliferação de Células
/
Retinopatia Diabética
/
Fundo de Olho
/
Degeneração Macular
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
Limite:
Humans
Idioma:
En
Revista:
PLoS One
Assunto da revista:
CIENCIA
/
MEDICINA
Ano de publicação:
2019
Tipo de documento:
Article
País de afiliação:
Estados Unidos