Your browser doesn't support javascript.
loading
Barbed Sutures in Total Knee Arthroplasty: Are They Really Useful? A Randomized Controlled Trial.
Gamba, Carlo; Hinarejos, Pedro; Serrano-Chinchilla, Paula; Leal-Blanquet, Joan; Torres-Claramunt, Raul; Sánchez-Soler, Juan; Monllau, Joan Carles.
Afiliação
  • Gamba C; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Hinarejos P; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Serrano-Chinchilla P; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Leal-Blanquet J; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Torres-Claramunt R; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Sánchez-Soler J; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
  • Monllau JC; Department of Trauma and Orthopaedic, Hospital del Mar, Universitat Autonoma Barcelona, Barcelona, Spain.
J Knee Surg ; 33(9): 927-930, 2020 Sep.
Article em En | MEDLINE | ID: mdl-31108557
ABSTRACT
Bidirectional barbed sutures (BBSs) have recently been investigated in total knee arthroplasty (TKA). The contrasting results from the scarce literature suggest that BBSs are safe, save time and money, and give results comparable to traditional sutures. The purpose of the study is to test the real effect of BBSs on closure time in TKA and assess the functional results as well as the complications related to them. It was a randomized controlled trial. Eighty-five patients undergoing primary TKA were assigned to receive traditional closure with Vicryl (V-group) or with BBSs (Q-group). The exclusion criteria were significant coronal deformity, flexion contracture, or the need for stem and/or augmentation. The closure time for the capsule and that for the subcutaneous layer were registered separately. Intraoperative incidences were recorded. The follow-up was up to 1 month, during which the range of motion (ROM), superficial or deep infection, and wound dehiscence were assessed. There was a significant reduction in the capsule layer (27 seconds; p = 0.02) and global time closure (51 seconds; p = 0.01) in the Q-group. No differences were found in the subcutaneous layer (24 seconds; p = 0.055). There were more intraoperative suture breakages in the Q-group, mainly in the subcutaneous layer (p < 0.001). No differences in terms of dehiscence, infection, and ROM were observed at the 1-month follow-up. BBSs allow for slightly faster wound closure than Vicryl during a TKA. However, the differences observed have minimal clinical repercussions. Moreover, no differences in the infection rate (deep or superficial), dehiscence, or ROM were found.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Suturas / Artroplastia do Joelho Tipo de estudo: Clinical_trials Limite: Aged / Female / Humans / Male Idioma: En Revista: J Knee Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Suturas / Artroplastia do Joelho Tipo de estudo: Clinical_trials Limite: Aged / Female / Humans / Male Idioma: En Revista: J Knee Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Espanha