Your browser doesn't support javascript.
loading
Towards FLASH proton therapy: the impact of treatment planning and machine characteristics on achievable dose rates.
van de Water, Steven; Safai, Sairos; Schippers, Jacobus M; Weber, Damien C; Lomax, Antony J.
Afiliação
  • van de Water S; Center for Proton Therapy, Paul Scherrer Institute , Villigen , Switzerland.
  • Safai S; Center for Proton Therapy, Paul Scherrer Institute , Villigen , Switzerland.
  • Schippers JM; Center for Proton Therapy, Paul Scherrer Institute , Villigen , Switzerland.
  • Weber DC; Department of Radiation Therapy, Rijksuniversiteit Groningen , Groningen , the Netherlands.
  • Lomax AJ; Center for Proton Therapy, Paul Scherrer Institute , Villigen , Switzerland.
Acta Oncol ; 58(10): 1463-1469, 2019 Oct.
Article em En | MEDLINE | ID: mdl-31241377
ABSTRACT

Background:

This study aimed at evaluating spatially varying instantaneous dose rates for different intensity-modulated proton therapy (IMPT) planning strategies and delivery scenarios, and comparing these with FLASH dose rates (>40 Gy/s). Material and

methods:

In order to quantify dose rates in three-dimensions, we proposed the 'dose-averaged dose rate' (DADR) metric, defined for each voxel as the dose-weighted mean of the instantaneous dose rates of all spots (i.e., pencil beams). This concept was applied to four head-and-neck cases, each planned with clinical (4 fields) and various spot-reduced IMPT techniques 'standard' (4 fields), 'arc' (120 fields) and 'arc-shoot-through' (120 fields; 229 MeV only). For all plans, different delivery scenarios were simulated constant beam intensity, variable beam intensity for a clinical Varian ProBeam system, varied per energy layer or per spot, and theoretical spot-wise variable beam intensity (i.e., no monitor/safety limitations). DADR distributions were calculated assuming 2-Gy or 6-Gy fractions.

Results:

Spot-reduced plans contained 17-52 times fewer spots than clinical plans, with no deterioration of plan quality. For the clinical plans, the mean DADR in normal tissue for 2-Gy fractionation was 1.7 Gy/s (median over all patients) at maximum, whereas in standard spot-reduced plans it was 0.7, 4.4, 7.1, and 12.1 Gy/s, for the constant, energy-layer-wise, spot-wise, and theoretical spot-wise delivery scenarios, respectively. Similar values were observed for arc plans. Arc-shoot-through planning resulted in DADR values of 3.0, 6.0, 14.1, and 24.4 Gy/s, for the abovementioned scenarios. Hypofractionation (3×) generally resulted in higher dose rates, up to 73.2 Gy/s for arc-shoot-through plans. The DADR was inhomogeneously distributed with highest values at beam entrance and at the Bragg peak.

Conclusion:

FLASH dose rates were not achieved for conventional planning and clinical spot-scanning machines. As such, increased spot-wise beam intensities, spot-reduced planning, hypofractionation and arc-shoot-through plans were required to achieve FLASH compatible dose rates.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Fracionamento da Dose de Radiação / Radioterapia de Intensidade Modulada / Terapia com Prótons / Neoplasias de Cabeça e Pescoço Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Acta Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Planejamento da Radioterapia Assistida por Computador / Fracionamento da Dose de Radiação / Radioterapia de Intensidade Modulada / Terapia com Prótons / Neoplasias de Cabeça e Pescoço Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Acta Oncol Assunto da revista: NEOPLASIAS Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Suíça