Your browser doesn't support javascript.
loading
Compatibility of [99mTc]Tc-EDDA/HYNIC-TOC and [68Ga] Ga-DOTA-TOC in a syringe for intravenous administration.
Chaib, Sarah; Hallouard, François; Chennell, Philip; Darcissac, Caroline; Morelec, Isabelle; Rioufol, Catherine; Sautou, Valérie; Fraysse, Marc.
Afiliação
  • Chaib S; Hospices Civils de Lyon, Centre Hospitalier de Lyon Sud, Service de Pharmacie, unité de radiopharmacie, Pierre-Bénite.
  • Hallouard F; Hospices Civils de Lyon, Centre Hospitalier de Lyon Sud, Service de Pharmacie, unité de radiopharmacie, Pierre-Bénite.
  • Chennell P; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont-Ferrand, ICCF, UFR Pharmacie, Clermont-Ferrand.
  • Darcissac C; Hospices Civils de Lyon, Centre Hospitalier de Lyon Sud, Service de Pharmacie, unité de radiopharmacie, Pierre-Bénite.
  • Morelec I; Hospices Civils de Lyon, Centre Hospitalier de Lyon Sud, Service de médecine nucléaire, Pierre-Bénite.
  • Rioufol C; Hospices Civils de Lyon, Centre Hospitalier de Lyon Sud, Service de Pharmacie, unité de radiopharmacie, Pierre-Bénite.
  • Sautou V; Université de Lyon, Université Lyon 1, EMR 3738, Ciblage thérapeutique en Oncologie (CTO), Oullins, France.
  • Fraysse M; Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont-Ferrand, ICCF, UFR Pharmacie, Clermont-Ferrand.
Nucl Med Commun ; 41(1): 11-17, 2020 Jan.
Article em En | MEDLINE | ID: mdl-31764593
ABSTRACT

OBJECTIVE:

Drug quality in medical devices is not evaluated during the marketing authorization of radiopharmaceuticals. Therefore, the extemporaneous change of packaging made for preparation of patient unit doses in a syringe is the responsibility of radiopharmacists. The present study aimed to determine the impact of packaging and storage in a polypropylene syringe on the quality of hydrophilic drugs [Tc]Tc-EDDA/HYNIC-TOC (Tektrotyd) and [Ga]Ga-DOTA-TOC (Somakit-TOC).

METHODS:

Appearance, pH, radiochemical purity, sterility, and endotoxin tests were performed according the current European Pharmacopoeia. Subvisible and visible particles tests of the European Pharmacopoeia were adapted due to limited preparation volume (<25 ml). Sorption tests were performed according to the literature.

RESULTS:

After 2 h storage in a syringe, drug sorption of Tektrotyd and Somakit-TOC was of less than 2.5% and similar to other Tc-radiopharmaceuticals (range from 1.1 ± 0.5% to 4.2 ± 0.6%). For Tektrotyd, this sorption phenomenon was positively influenced by the drug concentration and a short contact with the medical device (4.8 ± 0.2% up to 5 s vs. 2.3 ± 0.2%, n = 4; P < 0.001). For Somakit-TOC, the duration of contact with syringe had no impact (1.6 ± 0.2% up to 5 s vs. 1.7 ± 0.6%; P = 1.000). No drug radiolysis or alteration of microbiological aspects were observed. No impurity from a 3-piece-syringe was observed according to drug aspect, pH, and subvisible and visible particles, which remained within specification of the current European Pharmacopoeia.

CONCLUSION:

This study found that drug sorption to packaging was compatible with clinical use and absence of drug alteration of Tektrotyd and Somakit-TOC after repackaging in a syringe in polypropylene and prolonged storage during 2 h.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Octreotida / Compostos de Organotecnécio / Ácido Edético / Administração Intravenosa Idioma: En Revista: Nucl Med Commun Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Octreotida / Compostos de Organotecnécio / Ácido Edético / Administração Intravenosa Idioma: En Revista: Nucl Med Commun Ano de publicação: 2020 Tipo de documento: Article