Multiplexed label-free electrochemical immunosensor for breast cancer precision medicine.
Cotchim, Suparat; Thavarungkul, Panote; Kanatharana, Proespichaya; Limbut, Warakorn.
Afiliação
  • Cotchim S; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Chemistry, Faculty of Science,
  • Thavarungkul P; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Physics, Faculty of Science, P
  • Kanatharana P; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Chemistry, Faculty of Science,
  • Limbut W; Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90112, Thailand; Department of Applied Science, Faculty of Sc
Anal Chim Acta ; 1130: 60-71, 2020 Sep 15.
Article em En | MEDLINE | ID: mdl-32892939
ABSTRACT
A novel multiplexed label-free electrochemical immunosensor was fabricated using graphene/methylene blue-chitosan/antibody and bovine serum albumin on indium tin oxide glass electrode for the simultaneous determination of three types of tumor markers including carcinoembryonic antigen (CEA), cancer antigens 153 (CA153), and cancer antigen 125 (CA125). Cyclic voltammetry, electrochemical impedance spectroscopy, and scanning electron microscopy were employed to monitor each fabrication step. Under the optimized experiment conditions, the immunosensor exhibited good reproducibility and selectivity with linear ranges of 0.10-1.00 pg mL-1 and 1.00-100.00 pg mL-1 for CEA, 0.10-2.50 mU mL-1 and 2.50-100.00 mU mL-1 for CA153, 0.10-2.50 mU mL-1 and 2.50-100.00 mU mL-1 for CA125, a detection limit of 0.04 pg mL-1 for CEA, 0.04 mU mL-1 for CA153, and 0.04 mU mL-1 for CA125. This electrochemical immunosensor was successfully applied to detect three tumor markers in blood serum samples with good recoveries. The reliability of the electrochemical immunosensor to detect three tumor markers in blood serum samples was in good agreement (P > 0.05) with that of the enzyme-linked fluorescent assay method.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Técnicas Biossensoriais Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2020 Tipo de documento: Article