Application of capillary electrophoresis-nano-electrospray ionization-mass spectrometry for the determination of N-nitrosodimethylamine in pharmaceuticals.
Remínek, Roman; Foret, Frantisek; Chung, Doo Soo.
Afiliação
  • Remínek R; Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Brno, Czech Republic.
  • Foret F; Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Brno, Czech Republic.
  • Chung DS; Department of Chemistry, Seoul National University, Seoul, Korea.
Electrophoresis ; 42(4): 334-341, 2021 02.
Article em En | MEDLINE | ID: mdl-33368407
ABSTRACT
After a presence of highly hepatotoxic and potentially carcinogenic N-nitrosodimethylamine was detected in certain lots of sartan, ranitidine, metformin, and other pharmaceuticals, local regulatory authorities issued recalls of suspected products, and concerns of the pharmacotherapy safety were widely discussed. Since then, testing of a representative sample of each produced lot of these pharmaceuticals is required as a part of quality control processes. Hence, an interface-free CE-nanoESI system coupled with MS detection was employed for the development of a simple and economical method for quantitative detection of this contaminant in the valsartan drug substances and finished formulations used as model matrices. In this arrangement, a fused-silica capillary was used as both a separation column and a nanoESI emitter providing high ionization efficiency and sensitivity. The optimized procedure was found to have sufficient selectivity, linearity, accuracy, and precision. The established LOD and LOQ values were 0.3 and 1.0 ng/mL, respectively. The practical applicability of the method was tested by analyses of commercially available Valsacor® tablets. The results obtained prove that the developed procedure represents a promising alternative to currently available GC- and LC-based methods. Furthermore, after an adjustment of the separation conditions, the CE-nanoESI/MS system can be conceptually used for the determination of NDMA in other suspected pharmaceuticals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Eletroforese Capilar / Espectrometria de Massas por Ionização por Electrospray / Dimetilnitrosamina Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Electrophoresis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: República Tcheca

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Eletroforese Capilar / Espectrometria de Massas por Ionização por Electrospray / Dimetilnitrosamina Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Electrophoresis Ano de publicação: 2021 Tipo de documento: Article País de afiliação: República Tcheca