Effective energy assessment during breast cancer intraoperative radiotherapy by low-energy X-rays: A Monte Carlo study.
Shamsabadi, Reza; Baghani, Hamid Reza; Mowlavi, Ali Asghar; Azadegan, Behnam.
Afiliação
  • Shamsabadi R; Physics Department, Hakim Sabzevari University, Daneshgah Blvd, P.O. 9617976487, Sabzevar, Iran.
  • Baghani HR; Physics Department, Hakim Sabzevari University, Daneshgah Blvd, P.O. 9617976487, Sabzevar, Iran. Hamidreza.baghani@gmail.com.
  • Mowlavi AA; Physics Department, Hakim Sabzevari University, Daneshgah Blvd, P.O. 9617976487, Sabzevar, Iran.
  • Azadegan B; Physics Department, Hakim Sabzevari University, Daneshgah Blvd, P.O. 9617976487, Sabzevar, Iran.
Radiat Environ Biophys ; 60(1): 125-134, 2021 03.
Article em En | MEDLINE | ID: mdl-33389050
ABSTRACT
The study reported in the present paper aimed to evaluate the effective energy (Eeff) of X-rays emitted from the surface of a bare X-ray probe and from different spherical applicators with various diameters, which are widely employed for low kV intraoperative radiotherapy (IORT) of breast cancer. A previously validated Monte Carlo model of the INTRABEAM system along with applicator diameters of 1.5-5 cm (with 0.5 cm increments) was employed for this purpose. The results show that the presence of the applicator can considerably harden the X-rays produced by the bare probe so that Eeff increases by a factor of about 2.6. Variations of applicator diameter also affects the X-ray effective energy. Specifically, increasing the applicator diameter from 1.5 to 3 cm and 3.5-5 cm resulted in an increase in the Eeff by 8.8% and 14.6%, respectively. The validity of the calculated Eeff values was confirmed by a reasonable agreement between the obtained probability density distributions (PDDs) for the full X-ray energy spectrum and those for the corresponding single effective energies, for different applicator diameters. The Eeff values obtained for different applicator diameters and the bare probe alone can be used as an alternative for the corresponding full energy spectra, in Monte Carlo-based dosimetry simulations of low-energy therapeutic X-rays, as well as for determining quality conversion factors of any ion chambers employed for low kV-IORT absolute dosimetry.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Terapia por Raios X / Neoplasias da Mama / Modelos Biológicos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Female / Humans Idioma: En Revista: Radiat Environ Biophys Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irã

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Tipos_de_cancer / Outros_tipos / Tratamento / Radioterapia Base de dados: MEDLINE Assunto principal: Terapia por Raios X / Neoplasias da Mama / Modelos Biológicos Tipo de estudo: Health_economic_evaluation / Prognostic_studies Limite: Female / Humans Idioma: En Revista: Radiat Environ Biophys Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Irã