Ultraprotective ventilation allowed by extracorporeal CO2 removal improves the right ventricular function in acute respiratory distress syndrome patients: a quasi-experimental pilot study.
Goursaud, Suzanne; Valette, Xavier; Dupeyrat, Julien; Daubin, Cédric; du Cheyron, Damien.
Afiliação
  • Goursaud S; CHU de Caen Normandie, Service de Réanimation Médicale, Av côte de Nacre, 14000, Caen, France. goursaud-s@chu-caen.fr.
  • Valette X; Normandie Univ, UNICAEN, INSERM, U1237, PhIND "Physiopathology and Imaging of Neurological Disorders", Institut Blood and Brain @ Caen-Normandie, Cyceron, 14000, Caen, France. goursaud-s@chu-caen.fr.
  • Dupeyrat J; CHU de Caen Normandie, Service de Réanimation Médicale, Av côte de Nacre, 14000, Caen, France.
  • Daubin C; CHU de Caen Normandie, Service de Réanimation Médicale, Av côte de Nacre, 14000, Caen, France.
  • du Cheyron D; CHU de Caen Normandie, Service de Réanimation Médicale, Av côte de Nacre, 14000, Caen, France.
Ann Intensive Care ; 11(1): 3, 2021 Jan 07.
Article em En | MEDLINE | ID: mdl-33411146
ABSTRACT

BACKGROUND:

Right ventricular (RV) failure is a common complication in moderate-to-severe acute respiratory distress syndrome (ARDS). RV failure is exacerbated by hypercapnic acidosis and overdistension induced by mechanical ventilation. Veno-venous extracorporeal CO2 removal (ECCO2R) might allow ultraprotective ventilation with lower tidal volume (VT) and plateau pressure (Pplat). This study investigated whether ECCO2R therapy could affect RV function.

METHODS:

This was a quasi-experimental prospective observational pilot study performed in a French medical ICU. Patients with moderate-to-severe ARDS with PaO2/FiO2 ratio between 80 and 150 mmHg were enrolled. An ultraprotective ventilation strategy was used with VT at 4 mL/kg of predicted body weight during the 24 h following the start of a low-flow ECCO2R device. RV function was assessed by transthoracic echocardiography (TTE) during the study protocol.

RESULTS:

The efficacy of ECCO2R facilitated an ultraprotective strategy in all 18 patients included. We observed a significant improvement in RV systolic function parameters. Tricuspid annular plane systolic excursion (TAPSE) increased significantly under ultraprotective ventilation compared to baseline (from 22.8 to 25.4 mm; p < 0.05). Systolic excursion velocity (S' wave) also increased after the 1-day protocol (from 13.8 m/s to 15.1 m/s; p < 0.05). A significant improvement in the aortic velocity time integral (VTIAo) under ultraprotective ventilation settings was observed (p = 0.05). There were no significant differences in the values of systolic pulmonary arterial pressure (sPAP) and RV preload.

CONCLUSION:

Low-flow ECCO2R facilitates an ultraprotective ventilation strategy thatwould improve RV function in moderate-to-severe ARDS patients. Improvement in RV contractility appears to be mainly due to a decrease in intrathoracic pressure allowed by ultraprotective ventilation, rather than a reduction of PaCO2.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Ann Intensive Care Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Revista: Ann Intensive Care Ano de publicação: 2021 Tipo de documento: Article País de afiliação: França