Measurement of 227Ac impurity in 225Ac using decay energy spectroscopy.
Tollefson, A D; Smith, C M; Carpenter, M H; Croce, M P; Fassbender, M E; Koehler, K E; Lilley, L M; O'Brien, E M; Schmidt, D R; Stein, B W; Ullom, J N; Yoho, M D; Mercer, D J.
Afiliação
  • Tollefson AD; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Smith CM; Los Alamos National Laboratory, Los Alamos, NM 87545, USA. Electronic address: cmsmith@lanl.gov.
  • Carpenter MH; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Croce MP; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Fassbender ME; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Koehler KE; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Lilley LM; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • O'Brien EM; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Schmidt DR; NIST Boulder Laboratories, Boulder, CO 80305, USA.
  • Stein BW; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Ullom JN; NIST Boulder Laboratories, Boulder, CO 80305, USA; University of Colorado, Boulder, CO 80309, USA.
  • Yoho MD; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
  • Mercer DJ; Los Alamos National Laboratory, Los Alamos, NM 87545, USA.
Appl Radiat Isot ; 172: 109693, 2021 Jun.
Article em En | MEDLINE | ID: mdl-33774323
ABSTRACT
225Ac is a valuable medical radionuclide for targeted α therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small changes in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and 100% detection efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from α decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 ± 0.005)% for a single production sample. This demonstration has shown that DES is a useful tool for quantitative measurements of complicated spectra.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Análise Espectral / Actínio Tipo de estudo: Prognostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Análise Espectral / Actínio Tipo de estudo: Prognostic_studies Idioma: En Revista: Appl Radiat Isot Assunto da revista: MEDICINA NUCLEAR / SAUDE AMBIENTAL Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Estados Unidos