Your browser doesn't support javascript.
loading
Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report.
Blessberger, Hermann; Kellermair, Joerg; Kammler, Juergen; Steinwender, Clemens; Zierer, Andreas F.
Afiliação
  • Blessberger H; Department of Cardiology, Kepler University Hospital, Medical Faculty, Johannes Kepler University, Linz.
  • Kellermair J; Department of Cardiology, Kepler University Hospital, Medical Faculty, Johannes Kepler University, Linz.
  • Kammler J; Department of Cardiology, Kepler University Hospital, Medical Faculty, Johannes Kepler University, Linz.
  • Steinwender C; Department of Internal Medicine II, Paracelsus Medical University, Salzburg.
  • Zierer AF; Department of Cardiology, Kepler University Hospital, Medical Faculty, Johannes Kepler University, Linz.
Medicine (Baltimore) ; 100(21): e26148, 2021 May 28.
Article em En | MEDLINE | ID: mdl-34032769
ABSTRACT
RATIONALE Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P2)/segment 3 of the posterior mitral valve leaflet (P3) 4 years before. DIAGNOSES Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords.

INTERVENTIONS:

After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance.

OUTCOMES:

The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.
Assuntos

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Cirurgia_oncologica Base de dados: MEDLINE Assunto principal: Cordas Tendinosas / Procedimentos Cirúrgicos Minimamente Invasivos / Implante de Prótese de Valva Cardíaca / Insuficiência da Valva Mitral Tipo de estudo: Guideline / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Temas: Geral / Cirurgia_oncologica Base de dados: MEDLINE Assunto principal: Cordas Tendinosas / Procedimentos Cirúrgicos Minimamente Invasivos / Implante de Prótese de Valva Cardíaca / Insuficiência da Valva Mitral Tipo de estudo: Guideline / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Revista: Medicine (Baltimore) Ano de publicação: 2021 Tipo de documento: Article