Your browser doesn't support javascript.
loading
Back-Table Modified Stent-Graft for Endovascular Repair of Ascending Aorta.
Shi, Juan; Liu, Ligang; Wei, Xiang; Ma, Mingjia.
Afiliação
  • Shi J; Division of Cardiothoracic and Vascular Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Liu L; Division of Cardiothoracic and Vascular Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Wei X; Division of Cardiothoracic and Vascular Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
  • Ma M; Division of Cardiothoracic and Vascular Surgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China.
J Endovasc Ther ; 28(6): 888-896, 2021 Dec.
Article em En | MEDLINE | ID: mdl-34190632
OBJECTIVES: To investigate the effectiveness of modified stent-grafts (SGs) for the management of ascending aortic pathologies. MATERIALS AND METHODS: From January 2015 to December 2019, 31 individuals were treated by ascending aortic endovascular repair with a back-table modified SG for acute (n=4) or chronic (n=1) type A aortic dissections, penetrating aortic ulcers (n=18), pseudoaneurysms (n=2), anastomotic fistula (n=1), and endoleaks after thoracic endovascular aortic repair (TEVAR) (n=5). The commercially available thoracic aortic SGs were modified with a fenestration or truncation technique on the back-table according to aortography during the operation. RESULTS: The 30-day mortality and aorta-related mortality rates were 12.9% and 6.5%, respectively. There were 2 strokes, 3 respiratory insufficiencies, and 6 endoleaks during hospitalization. During a mean follow-up of 28.8±16.6 months, the overall survival rates at 1 year and 3 years were both 80.6%. Free from adverse event rates at 1 year and 3 years were 88.9% and 84.7%, respectively. There were 2 deaths during follow-up: One patient died of cachexia 1 month after discharge, and the other patient died of acute myocardial infarction 3 months after discharge. One patient with a pseudoaneurysm underwent open ascending aorta replacement 3 months after discharge for a type Ia endoleak. Another patient suffered from cerebellar infarction 17 months after discharge. CONCLUSION: The modified SG for endovascular repair of the ascending aorta is a practicable alternative and presents acceptable outcomes in high-risk patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Endovasc Ther Assunto da revista: ANGIOLOGIA Ano de publicação: 2021 Tipo de documento: Article País de afiliação: China