Patient-specific 3D-printed shelf implant for the treatment of hip dysplasia: Anatomical and biomechanical outcomes in a canine model.
Willemsen, Koen; Tryfonidou, Marianna; Sakkers, Ralph; Castelein, René M; Zadpoor, Amir A; Seevinck, Peter; Weinans, Harrie; Meij, Björn; van der Wal, Bart C H.
Afiliação
  • Willemsen K; Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Tryfonidou M; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
  • Sakkers R; Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Castelein RM; Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Zadpoor AA; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
  • Seevinck P; Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Weinans H; Department of Orthopedics, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Meij B; Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands.
  • van der Wal BCH; Department of Clinical Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
J Orthop Res ; 40(5): 1154-1162, 2022 05.
Article em En | MEDLINE | ID: mdl-34191341
ABSTRACT
A solution for challenging hip dysplasia surgery could be a patient-specific 3D-printed shelf implant that is positioned extra-articular and restores the dysplastic acetabular rim to normal anatomical dimensions. The anatomical correction and biomechanical stability of this concept were tested in a canine model that, like humans, also suffers from hip dysplasia. Using 3D reconstructed computed tomography images the 3D shelf implant was designed to restore the radiological dysplastic hip parameters to healthy parameters. It was tested ex vivo on three dog cadavers (six hips) with hip dysplasia. Each hip was subjected to a biomechanical subluxation test, first without and then with the 3D shelf implant in place. Subsequently, an implant failure test was performed to test the primary implant fixation. At baseline, the dysplastic hips had an average Norberg angle of 88 ± 3° and acetabular coverage of 47 ± 2% and subluxated at an average of 83 ± 2° of femoral adduction. After adding the patient-specific shelf implants the dysplastic hips had an average Norberg angle of 122 ± 2° and acetabular coverage of 67 ± 3% and subluxated at an average of 117 ± 2° of femoral adduction. Implant failure after primary implant fixation occurred at an average of 1330 ± 320 Newton. This showed that the patient-specific shelf implants significantly improved the coverage and stability of dysplastic hips in a canine model with naturally occurring hip dysplasia. The 3D shelf is a promising concept for treating residual hip dysplasia with a straightforward technology-driven approach; however, the clinical safety needs to be further investigated in an experimental proof-of-concept animal study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Luxação Congênita de Quadril / Luxação do Quadril Tipo de estudo: Observational_studies Limite: Animals / Humans Idioma: En Revista: J Orthop Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Assunto principal: Luxação Congênita de Quadril / Luxação do Quadril Tipo de estudo: Observational_studies Limite: Animals / Humans Idioma: En Revista: J Orthop Res Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Holanda