Clinically translatable formulation strategies for systemic administration of nerve-specific probes.
Barth, Connor W; Shah, Vidhi M; Wang, Lei G; Antaris, Alexander L; Klaassen, Alwin; Sorger, Jonathan; Rao, Deepa A; Kerr, Darcy A; Henderson, Eric R; Alani, Adam W G; Gibbs, Summer L.
Afiliação
  • Barth CW; Biomedical Engineering Department, Oregon Health & Science University, Portland, OR 97201.
  • Shah VM; Department of Pharmaceutical Sciences, College of Pharmacy, Oregon State University/OHSU, Portland, OR, 97201.
  • Wang LG; Biomedical Engineering Department, Oregon Health & Science University, Portland, OR 97201.
  • Antaris AL; Intuitive Surgical, Sunnyvale, CA 94086.
  • Klaassen A; Intuitive Surgical, Sunnyvale, CA 94086.
  • Sorger J; Intuitive Surgical, Sunnyvale, CA 94086.
  • Rao DA; School of Pharmacy, Pacific University, Hillsboro, OR 97123.
  • Kerr DA; Department of Pathology, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756.
  • Henderson ER; Geisel School of Mdicine at Dartmouth College, Hanover, NH 03755.
  • Alani AWG; Department of Orthopaedics, Dartmouth-Hitchcock Medical Center, Lebanon, NH 03756.
  • Gibbs SL; Biomedical Engineering Department, Oregon Health & Science University, Portland, OR 97201.
Adv Ther (Weinh) ; 4(7)2021 Jul.
Article em En | MEDLINE | ID: mdl-34423111
Nerves are extremely difficult to identify and are often accidently damaged during surgery, leaving patients with lasting pain and numbness. Herein, a novel near-infrared (NIR) nerve-specific fluorophore, LGW01-08, was utilized for enhanced nerve identification using fluorescence guided surgery (FGS), formulated using clinical translatable strategies. Formulated LGW01-08 was examined for toxicology, pharmacokinetics (PK), and pharmacodynamics (PD) parameters in preparation for future clinical translation. Optimal LGW01-08 imaging doses were identified in each formulation resulting in a 10x difference between the toxicity to imaging dose window. Laparoscopic swine surgery completed using the da Vinci surgical robot (Intuitive Surgical) demonstrated the efficacy of formulated LGW01-08 for enhanced nerve identification. NIR fluorescence imaging enabled clear identification of nerves buried beneath ~3 mm of tissue that were unidentifiable by white light imaging. These studies provide a strong basis for future clinical translation of NIR nerve-specific fluorophores for utility during FGS to improve patient outcomes.

Texto completo: 1 Coleções: 01-internacional Temas: Geral Base de dados: MEDLINE Idioma: En Revista: Adv Ther (Weinh) Ano de publicação: 2021 Tipo de documento: Article